Yellow
Device
Test
Series
Parameter
Symbol Min. Typ. Max. Units
Conditions
HDSP-
U3xx
Luminous Intensity/Segment[1,2]
(Digit Average)
IV
225
480
2740
2.2
µcd
IF = 5 mA
IF = 20 mA
IF = 20 mA
Forward Voltage/Segment or DP
Peak Wavelength
Dominant Wavelength[3,5]
Reverse Voltage/Segment or DP[4]
Temperature Coefficient of
VF
λPEAK
λd
2.5
V
nm
583
581.5 586
592.5
nm
VR
3.0
50.0
-2
V
IR = 100 µA
∆V /°C
mV/°C
F
V /Segment or DP
F
Thermal Resistance LED
Junction-to-Pin
RθJ-Pin
200
°C/W/
Seg
High Performance Green
Device
Series
Test
Conditions
Parameter
Symbol Min. Typ. Max. Units
HDSP-
U5xx
Luminous Intensity/Segment[1,2]
(Digit Average)
IV
860 3000
6800
2.1
µcd
IF = 10 mA
IF = 20 mA
IF = 10 mA
Forward Voltage/Segment or DP
Peak Wavelength
Dominant Wavelength[3,5]
Reverse Voltage/Segment or DP[4]
VF
λPEAK
λd
2.5
V
nm
566
571
nm
VR
3.0
50.0
-2
V
IR = 100 µA
Temperature Coefficient of
VF/Segment or DP
∆V /°C
mV/°C
F
Thermal Resistance LED
Junction-to-Pin
RθJ-Pin
200
°C/W/
Seg
Notes:
1. Case temperature of device immediately prior to the intensity measurement is 25°C.
2. The digits are categorized for luminous intensity. The intensity category is designated by a letter on the side of the package.
3. The dominant wavelength, λd, is derived from the CIE chromaticity diagram and is that single wavelength which defines the color of
the device.
4. Typical specification for reference only. Do not exceed absolute maximum ratings.
5. The Yellow (HDSP-U3XX) series and Green (HDSP-U5XX) series displays are categorized for dominant wavelength. The category is
designated by a number adjacent to the luminous intensity category letter.