IEC/EN/DIN EN 60747-5-2 Insulation Characteristics  
Description  
Symbol  
HCPL-7860 HCPL-786J  
Unit  
Installation classification per DIN VDE 0110/1.89, Table 1  
for rated mains voltage 300 Vrms  
I - IV  
I - III  
I - III  
I - II  
I - IV  
I - IV  
I - IV  
I - III  
for rated mains voltage 450 Vrms  
for rated mains voltage 600 Vrms  
for rated mains voltage 1000 Vrms  
Climatic Classification  
40/85/21  
2
40/85/21  
2
Pollution Degree (DIN VDE 0110/1.89)  
Maximum Working Insulation Voltage  
VIORM  
VPR  
891  
1230  
2306  
Vpeak  
Vpeak  
Input to Output Test Voltage, Method b [2]  
VIORM x 1.875=VPR, 100% Production Test with tm=1 sec,  
Partial discharge < 5 pC  
1670  
Input to Output Test Voltage, Method a[2]  
VIORM x 1.6=VPR, Type and Sample Test, tm=10 sec,  
Partial discharge < 5 pC  
VPR  
1425  
6000  
1968  
8000  
Vpeak  
Vpeak  
Highest Allowable Overvoltage(Transient Overvoltage tini = 60 sec)  
VIOTM  
Safety-limiting values - maximum values allowed in the event of a failure.  
Case Temperature  
Input Current [3]  
Output Power [3]  
TS  
175  
400  
600  
175  
400  
600  
°C  
mA  
mW  
IS, INPUT  
PS, OUTPUT  
Insulation Resistance at TS, VIO = 500 V  
RS  
>109  
>109  
Notes:  
800  
700  
600  
500  
400  
300  
1. Insulation characteristics are guaranteed only within the safety maximum ratings, which must  
be ensured by protective circuits within the application. Surface Mount Classifications is Class  
A in accordance with CECC00802.  
2. Refer to the optocoupler section of the Isolation and Control Components Designer’s Catalog,  
under Product Safety Regulations section, (IEC/EN/DIN EN 60747-5-2) for a detailed descrip-  
tion of Method a and Method b partial discharge test profiles.  
P
(mWꢀ  
S
IS (mAꢀ  
3. Refer to the following figure for dependence of P and I on ambient temperature.  
S
S
200  
100  
0
0
25 50 75 100 125 150 175 200  
TS - CASE TEMPERATURE - o  
C
Insulation and Safety Related Specifications  
Option 300 - surface mount classification is Class A in accordance with CECC 00802.  
Parameter  
Symbol  
DIP-8  
SO-16  
Units  
Conditions  
Minimum External Air Gap L(101)  
(Clearance)  
7.4  
8.3  
mm  
Measured from input terminals to output terminals,  
shortest distance through air.  
Minimum External Tracking L(102)  
(Creepage)  
8.0  
0.5  
8.3  
0.5  
mm  
mm  
Measured from input terminals to output terminals,  
shortest distance path along body.  
Minimum Internal Plastic  
Gap (Internal Clearance)  
Through insulation distance conductor to conductor,  
usually the straight line distance thickness between  
the emitter and detector.  
Tracking Resistance  
(Comparative Tracking  
Index)  
CTI  
>175  
IIIa  
>175  
IIIa  
V
DIN IEC 112/VDE 0303 Part 1  
Isolation Group  
Material Group (DIN VDE 0110, 1/89, Table 1)  
6