欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-4504-500 参数 Datasheet PDF下载

HCPL-4504-500图片预览
型号: HCPL-4504-500
PDF下载: 下载PDF文件 查看货源
内容描述: [暂无描述]
分类和应用: 光电
文件页数/大小: 19 页 / 200 K
品牌: AVAGO [ AVAGO TECHNOLOGIES LIMITED ]
 浏览型号HCPL-4504-500的Datasheet PDF文件第4页浏览型号HCPL-4504-500的Datasheet PDF文件第5页浏览型号HCPL-4504-500的Datasheet PDF文件第6页浏览型号HCPL-4504-500的Datasheet PDF文件第7页浏览型号HCPL-4504-500的Datasheet PDF文件第9页浏览型号HCPL-4504-500的Datasheet PDF文件第10页浏览型号HCPL-4504-500的Datasheet PDF文件第11页浏览型号HCPL-4504-500的Datasheet PDF文件第12页  
Regulatory Information  
The devices contained in this data sheet have been approved by the following agencies:  
Agency/Standard  
HCPL-4504  
HCPL-J454  
HCPL-0454  
HCNW4504  
UL1577  
3750 Vrms /  
1 minute,  
3750 Vrms /  
1 minute  
3750 Vrms /  
1 minute  
5000 Vrms /  
1 minute  
Underwriters Laboratories (UL)  
Recognized under UL1577,  
Option 020 5000  
Vrms / 1 minute  
Component Recognition Program,  
Category FPQU2, File E55361  
Component 3750 Vrms /  
3750 Vrms /  
1 minute  
3750 Vrms /  
1 minute  
5000 Vrms /  
1 minute  
Canadian Standards Association (CSA)  
File CA88324  
Acceptance  
Notice #5  
1 minute,  
Option 020 5000  
Vrms / 1 minute  
Option 060  
VIORM = 630 Vpeak  
VIORM = 891  
Vpeak  
Option 060  
VIORM = 560  
Vpeak  
VIORM = 1414  
Vpeak  
IEC/EN/DIN EN 60747-5-2  
Approved under:  
IEC 60747-5-2:1997 + A1:2002  
EN 60747-5-2:2001 + A1:2002  
DIN EN 60747-5-2 (VDE 0884 Teil 2):2003-01  
Insulation and Safety Related Specifications  
Value  
HCPL-  
J454  
HCPL-J454  
All other  
HCPL-  
HCPL-  
HCNW  
Parameter  
Symbol  
4504 -400E/-600E options  
0454  
4504 Units Conditions  
Minimum External  
Air Gap  
(External Clearance)  
L(101)  
7.1  
8.0  
7.4  
8.0  
4.9  
9.6  
mm Measured from input ter-  
minals to output terminals,  
shortest distance through air.  
Minimum External  
Tracking  
(External Creepage)  
L(102)  
7.4  
8.0  
4.8  
10.0  
mm Measured from input ter-  
minals to output terminals,  
shortest distance path along  
body.  
Minimum Internal  
Plastic Gap  
0.08  
0.5  
0.5  
0.08  
1.0  
mm Through insulation distance,  
conductor to conductor,  
(Internal Clearance)  
usually the direct distance  
between the photoemitter  
and photodetector inside the  
optocoupler cavity.  
Minimum Internal  
Tracking (Internal  
Creepage)  
NA  
≥175  
IIIa  
NA  
≥175  
IIIa  
NA  
≥175  
IIIa  
NA  
≥175  
IIIa  
4.0  
mm Measured from input ter-  
minals to output terminals,  
along internal cavity.  
Tracking Resistance  
(Comparative  
Tracking Index)  
CTI  
≥200 Volts DIN IEC 112/VDE 0303 Part 1  
Isolation Group  
IIIa  
Material Group (DIN VDE  
0110, 1/89, Table 1)  
All Avago data sheets report the creepage and clearance  
inherent to the optocoupler component itself. These di-  
mensions are needed as a starting point for the equip-  
ment designer when determining the circuit insulation  
requirements.  
creepage, the shortest distance path along the surface  
of a printed circuit board between the solder fillets of  
the input and output leads must be considered. There  
are recommended techniques such as grooves and ribs  
which may be used on a printed circuit board to achieve  
desired creepage and clearances. Creepage and clear-  
ance distances will also change depending on factors  
such as pollution degree and insulation level.  
However, once mounted on a printed circuit board, mini-  
mum creepage and clearance requirements must be  
met as specified for individual equipment standards. For  
8