 浏览型号HCPL-4504-360E的Datasheet PDF文件第5页浏览型号HCPL-4504-360E的Datasheet PDF文件第6页浏览型号HCPL-4504-360E的Datasheet PDF文件第7页浏览型号HCPL-4504-360E的Datasheet PDF文件第8页浏览型号HCPL-4504-360E的Datasheet PDF文件第10页浏览型号HCPL-4504-360E的Datasheet PDF文件第11页浏览型号HCPL-4504-360E的Datasheet PDF文件第12页浏览型号HCPL-4504-360E的Datasheet PDF文件第13页  
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics  
HCPL-0454  
OPTION 060  
HCPL-4504  
OPTION 060  
Description  
Symbol  
HCPL-J454  
HCNW4504  
Unit  
Installation classification per  
DIN VDE 0110/1.89, Table 1  
for rated mains voltage ≤150 V rms  
for rated mains voltage ≤300 V rms  
for rated mains voltage ≤450 V rms  
for rated mains voltage ≤600 V rms  
for rated mains voltage ≤1000 V rms  
I-IV  
I-III  
I-IV  
I-IV  
I-III  
I-IV  
I-IV  
I-III  
I-III  
I-IV  
I-IV  
I-IV  
I-IV  
I-III  
Climatic Classification  
55/100/21  
55/100/21  
55/100/21  
55/85/21  
2
Pollution Degree (DIN VDE 0110/1.89)  
Maximum Working Insulation Voltage  
Input to Output Test Voltage, Method b*  
2
2
2
V
IORM  
560  
630  
891  
1414  
V peak  
V peak  
V
IORM x 1.875 = VPR, 100% Production  
VPR  
1050  
840  
1181  
945  
1670  
1336  
6000  
2652  
2121  
8000  
Test with tm = 1 sec,  
Partial Discharge < 5 pC  
Input to Output Test Voltage, Method a*  
VIORM x 1.5 = VPR, Type and Sample  
VPR  
V peak  
Test, tm = 60 sec,  
Partial Discharge < 5 pC  
Highest Allowable Overvoltage*  
(Transient Overvoltage, tini = 10 sec)  
Safety Limiting Values - Maximum  
Values Allowed in the Event of a Failure,  
also see Thermal Derating curve  
VIOTM  
4000  
6000  
V peak  
Case Temperature  
Input Current  
TS  
150  
150  
600  
≥109  
175  
230  
600  
≥109  
175  
400  
600  
≥109  
150  
400  
700  
≥109  
°C  
IS,INPUT  
PS,OUTPUT  
RS  
mA  
mW  
Ω
Output Power  
Insulation Resistance at TS,  
VIO = 500 V  
*Refer to the optocoupler section of the Designer's Catalog, under regulatory information (IEC/EN/DIN EN 60747-5-2) for a detailed description of  
Method a and Method b partial discharge test profiles.  
NOTE: These optocouplers are suitable for "safe electrical isolation" only within the safety limit data. Maintenance of the safety data shall be ensured  
by means of protective circuits.  
NOTE: Insulation Characteristics are per IEC/EN/DIN EN 60747-5-2.  
NOTE: Surface mount classification is Class A in accordance with CECC 00802.  