欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-3120-500E 参数 Datasheet PDF下载

HCPL-3120-500E图片预览
型号: HCPL-3120-500E
PDF下载: 下载PDF文件 查看货源
内容描述: 2.5安培输出电流IGBT栅极驱动光电耦合器 [2.5 Amp Output Current IGBT Gate Drive Optocoupler]
分类和应用: 栅极光电输出元件双极性晶体管栅极驱动
文件页数/大小: 24 页 / 507 K
品牌: AVAGO [ AVAGO TECHNOLOGIES LIMITED ]
 浏览型号HCPL-3120-500E的Datasheet PDF文件第4页浏览型号HCPL-3120-500E的Datasheet PDF文件第5页浏览型号HCPL-3120-500E的Datasheet PDF文件第6页浏览型号HCPL-3120-500E的Datasheet PDF文件第7页浏览型号HCPL-3120-500E的Datasheet PDF文件第9页浏览型号HCPL-3120-500E的Datasheet PDF文件第10页浏览型号HCPL-3120-500E的Datasheet PDF文件第11页浏览型号HCPL-3120-500E的Datasheet PDF文件第12页  
All Avago data sheets report the creepage and clearance 
inherent  to  the  optocoupler  component  itself.  These 
dimensions  are  needed  as  a  starting  point  for  the 
equipment designer when determining the circuit insula-
tion requirements. However, once mounted on a printed 
circuit board, minimum creep-age and clearance require-
ments must be met as specified for individual equipment 
standards. For creepage, the shortest distance path along 
the surface of a printed circuit board between the solder 
fillets of the input and output leads must be considered. 
There  are  recommended  techniques  such  as  grooves 
and ribs  which may  be  used  on a  printed  circuit board 
to  achieve  desired  creepage  and  clearances.  Creepage 
and clearance distances will also change depending on 
factors such as pollution degree and insulation level.
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics
Description
Installation classification per DIN VDE 0110/1.89, 
Table 1 
    for rated mains voltage ≤150 V rms 
    for rated mains voltage ≤300 V rms 
    for rated mains voltage ≤450 V rms 
    for rated mains voltage ≤600 V rms 
    for rated mains voltage ≤1000 V rms 
Climatic Classification 
Pollution Degree (DIN VDE 0110/1.89) 
Maximum Working Insulation Voltage 
Input to Output Test Voltage, Method b* 
  V
IORM
 x 1.875 = V
PR
, 100% Production Test, 
  t
m
 = 1 sec, Partial Discharge < 5pC 
Input to Output Test Voltage, Method a* 
  V
IORM
 x 1.5 = V
PR
, Type and Sample Test, 
  t
m
 = 60 sec, Partial Discharge < 5pC
Highest Allowable Overvoltage* 
  (Transient Overvoltage, t
ini
 = 10 sec) 
Safety Limiting Values – maximum values allowed 
in the event of a failure, also see Figure 37. 
      Case Temperature 
      Input Current 
      Output Power 
Insulation Resistance at T
S
, V
IO
 = 500 V 
Symbol
V
IORM
V
PR
V
PR
HCPL-3120
Option 060
I-IV 
I-IV 
I-III 
55/100/21 
2 
630 
1181 
945 
HCPL-J312
I-IV 
I-IV 
I-III 
I-III 
55/100/21 
2 
891 
1670 
1336 
HCNW3120
I-IV 
I-IV 
I-IV 
I-IV 
I-III
55/100/21
2
1414 
2652 
2121 
Unit
   
V
peak
V
peak
V
peak
V
IOTM
T
S
I
S INPUT
P
S OUTPUT
R
S
6000 
175 
230 
600 
≥10
9
6000 
175 
400 
600 
≥10
9
8000 
150 
400 
700 
≥10
9
V
peak
   
°C 
mA 
mW
Ω
*Refer to the IEC/EN/DIN EN 60747-5-2 section (page 1-6/8) of the Isolation Control Component Designer’s Catalog for a detailed description of 
Method a/b partial discharge test profiles.
Note: These optocouplers are suitable for “safe electrical isolation” only within the safety limit data. Maintenance of the safety data shall be en-
sured by means of protective circuits. Surface mount classification is Class A in accordance with CECC 00802.
8