Switching Specifications (AC)
Over recommended operating conditions (TA = 0 to 70°C), VCC = 5 V, unless otherwise specified.
Parameter
Sym.
Device
Min. Typ.**
Max.
TA =25°C
25*
Units Test Conditions
Fig.
Note
Propagation
Delay Time
to Logic Low
at Output
tPHL
6N139
HCPL-0701
HCNW139
6N139
HCPL-0701
HCNW139
6N138
HCPL-0700
HCNW138
6N139
HCPL-0701
HCNW139
6N139
5
30
2
s
IF = 0.5 mA,
5, 6,
7, 9,
12
2, 4
Rl = 4.7 k
0.2
1*
10*
60*
7*
s
IF = 12 mA,
Rl = 270
11
15
1.6
s
IF = 1.6 mA,
Rl = 2.2 k
11
90
Propagation
Delay Time
to Logic High
at Output
tPLH
18
s
IF = 0.5 mA,
5, 6,
7, 9,
12
2, 4
Rl = 4.7 k
115
10
2
10
s
IF = 12 mA,
HCPL-0701
HCNW139
6N138
Rl = 270
11
50
35*
s
IF = 1.6 mA,
HCPL-0700
HCNW138
Rl = 2.2 k
70
Common Mode
Transient
Immunity at
Logic High
Output
Common Mode
Transient
Immunity at
Logic Low
Output
|CMH|
|CML|
1000 10000
V/s
IF = 0 mA,
TA = 25°C
Rl = 2.2 k
|VCM| = 10
Vp-p
IF = 1.6 mA,
TA = 25°C
Rl = 2.2 k
|VCM| = 10
Vp-p
13
13
5, 6
5, 6
1000 10000
V/s
* JEDEC Registered Data for 6N139 and 6N138.
**All typical values at TA = 25°C and VCC = 5 V, unless otherwise noted.
11