Insulation and Safety Related Specifications
8-pin DIP
(300 Mil)
Value
7.1
Parameter
Minimum External
Air Gap
(External Clearance)
Minimum External
Tracking
(External Creepage)
Minimum Internal
Plastic Gap
(Internal Clearance)
Symbol
L(101)
SO-8
Value
4.9
Widebody
(400 Mil)
Value
9.6
Unit
mm
Conditions
Measured from input terminals
to output terminals, shortest
distance through air.
Measured from input terminals
to output terminals, shortest
distance path along body.
Through insulation distance,
conductor to conductor, usually
the direct distance between the
photoemitter and photodetector
inside the optocoupler cavity.
Measured from input terminals
to output terminals, along
internal cavity.
DIN IEC 112/VDE 0303 Part 1
Material Group
(DIN VDE 0110, 1/89, Table 1)
L(102)
7.4
4.8
10.0
mm
0.08
0.08
1.0
mm
Minimum Internal
Tracking
(Internal Creepage)
Tracking Resistance
CTI
(Comparative Tracking Index)
Isolation Group
NA
NA
4.0
mm
200
IIIa
200
IIIa
200
IIIa
V
Option 300 - surface mount classification is Class A in accordance with CECC 00802.
IEC/EN/DIN EN 60747-5-5 Insulation Characteristics*
(HCPL-06xx Option 060 Only)
Description
Installation classification per DIN VDE 0110, Table 1
for rated mains voltage ≤ 150 V
rms
for rated mains voltage ≤ 300 V
rms
for rated mains voltage ≤ 600 V
rms
Climatic Classification
Pollution Degree (DIN VDE 0110/39)
Maximum Working Insulation Voltage
Input-to-Output Test Voltage, Method b*
V
IORM
x 1.875 = V
PR
, 100% Production Test with t
m
= 1 sec,
Partial Discharge < 5 pC
Input-to-Output Test Voltage, Method a*
V
IORM
x 1.6 = V
PR
, Type and Sample Test, t
m
= 10 sec,
Partial Discharge < 5 pC
Highest Allowable Overvoltage
(Transient Overvoltage, t
ini
= 60 sec)
Safety Limiting Values (Maximum values allowed in the event of a failure)
Case Temperature
Input Current**
Output Power**
Insulation Resistance at T
S
, V
IO
= 500 V
V
IORM
V
PR
Symbol
Characteristic
I-IV
I-IV
I-III
40/85/21
2
567
1063
Unit
V
peak
V
peak
V
PR
907
V
peak
V
IOTM
T
S
6000
150
150
600
≥10
9
V
peak
°C
mA
mW
Ω
I
S,INPUT
P
S,OUTPUT
R
S
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN 60747-5-5, for a
detailed description.
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in application.
8