欢迎访问ic37.com |
会员登录 免费注册
发布采购

AS4SD16M16DG-75/IT 参数 Datasheet PDF下载

AS4SD16M16DG-75/IT图片预览
型号: AS4SD16M16DG-75/IT
PDF下载: 下载PDF文件 查看货源
内容描述: 256 MB : 16梅格×16 SDRAM同步动态随机存取存储 [256 MB: 16 Meg x 16 SDRAM Synchronous DRAM Memory]
分类和应用: 存储内存集成电路光电二极管动态存储器
文件页数/大小: 51 页 / 1075 K
品牌: AUSTIN [ AUSTIN SEMICONDUCTOR ]
 浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第6页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第7页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第8页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第9页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第11页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第12页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第13页浏览型号AS4SD16M16DG-75/IT的Datasheet PDF文件第14页  
SDRAM  
AS4SD16M16  
Austin Semiconductor, Inc.  
Data from any READ burst may be truncated with a  
subsequent READ command, and data from a fixed-length READ  
burst may be immediately followed by data from a READ  
command. In either case, a continuous flow of data can be  
maintained. The first data element from the new burst follows  
either the last element of a complete burst or the last desired  
data element of a longer burst that is being truncated. The new  
READ command should be issued x cycles before the clock  
edge at which the last desired data element is valid, where x  
equals the CAS latency minus one. This is shown in Figure 7  
for CAS latencies of two and three; data element n+3 is either  
the last of a burst of four or the last desired of a longer burst.  
The 256MB SDRAM uses a pipelined architecture and there-  
fore does not require the 2n rule associated with a prefetch  
architecture. A READ command can be initiated on any clock  
cycle following a previous READ command. Full-speed ran-  
dom read accesses can be performed to the same bank, as shown  
in Figure 8, or each subsequent READ may be performed to  
different bank.  
READs  
READ bursts are initiated with a READ command, as shown  
in Figure 5.  
The starting column and bank addresses are provided with  
the READ command, and auto precharge is either enabled or  
disabled for that burst access. If auto precharge is enabled, the  
row being accessed is precharged at the completion of the burst.  
For the generic READ commands used in the following  
illustrations, auto precharge is disabled.  
During READ bursts, the valid data-out element from the  
starting column address will be available following the CAS  
latency after the READ command. Each subsequent data-out  
element will be valid by the next positive clock edge. Figure 6  
shows general timing for each possible CAS latency setting.  
Upon completion of a burst, assuming no other commands  
have been initiated, the DQs will go High-Z. A full-page burst  
will continue until terminated. (At the end of the page, it will  
wrap to the start address and continue.)  
FIGURE 6: CAS Latency  
FIGURE 5: READ Command  
Austin Semiconductor, Inc. reserves the right to change products or specifications without notice.  
AS4SD16M16  
Rev. 1.0 11/02  
10