S78LxxL
S78L10 Electrical Characteristics
(VI=17V, IO=40 ㎃, TJ=0℃ ~ 125℃, Unless otherwise noted)
S78L10
Parameter
Test Conditions*
Unit
Min. Typ. Max.
25℃
9.6
9.5
10
10
10.4
10.5
IO=1mA to 40mA
VI=13V to 25V
Output Voltage**
V
0℃ to 125℃
IO=1mA to 70mA
9.5
37
10
51
42
44
20
11
62
1.7
4.2
10.5
175
125
VI=13V to 25V
VI=14V to 25V
25℃
0℃ to 25℃
25℃
Input regulation
Ripple rejection
Output regulation
mV
dB
VI=15V to 25V, f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
f=10Hz to 100KHz
90
40
mV
25℃
25℃
Output noise voltage
Dropout Voltage
uV
V
25℃
6
Bias current
125℃
5.5
1.5
0.1
mA
VI=14V to 25V
0℃ to 125℃
Bias Current Change
IO=1mA to 40mA
S78L12 Electrical Characteristics
(VI=19V, IO=40 ㎃, TJ=0℃ ~ 125℃, Unless otherwise noted)
S78L12
Parameter
Test Conditions*
Unit
Min. Typ. Max.
25℃
11.5
11.4
12
12
12.5
12.6
IO=1mA to 40mA
VI=14V to 27V
Output Voltage**
V
0℃ to 125℃
IO=1mA to 70mA
11.4
37
12
55
49
42
22
13
70
1.7
4.3
12.6
250
200
VI=14.5V to 27V
VI=16V to 27V
25℃
0℃ to 25℃
25℃
Input regulation
Ripple rejection
Output regulation
mV
dB
VI=15V to 25V, f=120Hz
IO=1mA to 100mA
IO=1mA to 40mA
100
50
mV
25℃
25℃
Output noise voltage
Dropout Voltage
f=10Hz to 100KHz
uV
V
25℃
6.5
6
Bias current
125℃
mA
VI=16V to 27V
1.5
0.1
0℃ to 125℃
Bias Current Change
IO=1mA to 40mA
* Pulse testing techniques are used to maintain the junction temperature as close to the ambient temperature as
possible. Thermal effects must be taken into account separately. All characteristics are measured with a 0.33uF
capacitor across the input and a 0.1uF capacitor across the output.
** This specification applies only for dc power dissipation permitted by absolute maximum ratings.
KSI-9048-001
5