S52xxM
Absolute Maximum Ratings
Characteristic
Ta=25°C
Unit
V
Symbol
VIN
Ratings
-0.4 ~+16
-0.4 ~+16
500
Input supply voltage
Enable Input Voltage
VEN
Pd
V
Power Dissipation
mW
°C
Junction Temperature Range
Storage Temperature Range
Lead Temperature Time
Tj
-40 ~+125
-60 ~+150
260 (5 Sec)
Tstg
Tsol
°C
°C
Electrical Characteristics
(※ VIN=VOUT+1V; IOUT = 100uA; CL=4.7uF; VEN≥2.0V; TJ=25℃)
Max
Unit
.
Characteristic
Symbol
Test Condition
Min. Typ.
Output voltage
VOUT
-
See Table 1
ÌVOUT
VOUT
/
/
line Regulation
VIN=VOUT+1V to 16V
-
0.3
8
5
mV
ÌVOUT
VOUT
Load Regulation
-
-
24
IOUT=1mA ~100mA
mV
uA
Quiescent Current
ICC
V
EN≤0.4V(shutdown)
0.01
400
500
150
250
10
1
500
600
250
450
50
* IOUT=50mA (VOUT=1.5V)
* IOUT=100mA (VOUT=1.5V)
* IOUT=50mA (VOUT =1.8V)
* IOUT=100mA (VOUT =1.8V)
* IOUT=100uA
-
-
-
-
-
-
Dropout Voltage
VDROP
mV
110
140
150
250
* IOUT=50mA
* IOUT=100mA
IOUT=50mA,VEN≥2.0(active)
-
1.5
3.0
(Vout=1.5V/1.8V)
Ground Pin Current
Output Noise
IGND
mA
IOUT=50mA, VEN≥2.0(active)
-
-
0.8
1.5
-
IOUT=50mA, CL=4.7uF
nV √ Hz
eno
260
470pF from BYP to GND
Enable Input Logic-Low Voltage
Enable Input Logic-High Voltage
VIL
VIH
IIL
Regulator Shutdown
-
1.6
-
-
-
0.4
-
V
V
Regulator enabled
VIL≤0.4V
0.01
5
1
Enable Input Current
uA
IIH
VIH≥2.0V
2
10
*Note1 : Dropout Voltage is the difference between the input voltage and the output voltage at whitch point the regulator
starts to fall out of regulation (this is the point when the output voltage decreases by 100mV).
KSI-2012-006