 浏览型号ATMEGA48PA-AU的Datasheet PDF文件第223页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第224页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第225页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第226页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第228页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第229页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第230页浏览型号ATMEGA48PA-AU的Datasheet PDF文件第231页  
ATmega48PA/88PA/168PA/328P  
21.7 Transmission Modes  
The TWI can operate in one of four major modes. These are named Master Transmitter (MT),  
Master Receiver (MR), Slave Transmitter (ST) and Slave Receiver (SR). Several of these  
modes can be used in the same application. As an example, the TWI can use MT mode to write  
data into a TWI EEPROM, MR mode to read the data back from the EEPROM. If other masters  
are present in the system, some of these might transmit data to the TWI, and then SR mode  
would be used. It is the application software that decides which modes are legal.  
The following sections describe each of these modes. Possible status codes are described  
along with figures detailing data transmission in each of the modes. These figures contain the  
following abbreviations:  
S: START condition  
Rs: REPEATED START condition  
R: Read bit (high level at SDA)  
W: Write bit (low level at SDA)  
A: Acknowledge bit (low level at SDA)  
A: Not acknowledge bit (high level at SDA)  
Data: 8-bit data byte  
P: STOP condition  
SLA: Slave Address  
In Figure 21-12 to Figure 21-18, circles are used to indicate that the TWINT Flag is set. The  
numbers in the circles show the status code held in TWSR, with the prescaler bits masked to  
zero. At these points, actions must be taken by the application to continue or complete the TWI  
transfer. The TWI transfer is suspended until the TWINT Flag is cleared by software.  
When the TWINT Flag is set, the status code in TWSR is used to determine the appropriate soft-  
ware action. For each status code, the required software action and details of the following serial  
transfer are given in Table 21-2 to Table 21-5. Note that the prescaler bits are masked to zero in  
these tables.  
21.7.1  
Master Transmitter Mode  
In the Master Transmitter mode, a number of data bytes are transmitted to a Slave Receiver  
(see Figure 21-11). In order to enter a Master mode, a START condition must be transmitted.  
The format of the following address packet determines whether Master Transmitter or Master  
Receiver mode is to be entered. If SLA+W is transmitted, MT mode is entered, if SLA+R is trans-  
mitted, MR mode is entered. All the status codes mentioned in this section assume that the  
prescaler bits are zero or are masked to zero.  