 浏览型号ATMEGA48V-10MI的Datasheet PDF文件第39页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第40页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第41页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第42页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第44页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第45页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第46页浏览型号ATMEGA48V-10MI的Datasheet PDF文件第47页  
ATmega48/88/168  
Figure 19. External Reset During Operation  
CC  
Brown-out Detection  
ATmega48/88/168 has an On-chip Brown-out Detection (BOD) circuit for monitoring the  
CC level during operation by comparing it to a fixed trigger level. The trigger level for  
V
the BOD can be selected by the BODLEVEL Fuses. The trigger level has a hysteresis to  
ensure spike free Brown-out Detection. The hysteresis on the detection level should be  
interpreted as VBOT+ = VBOT + VHYST/2 and VBOT- = VBOT - VHYST/2.  
Table 21. BODLEVEL Fuse Coding(1)  
BODLEVEL 2..0 Fuses  
Min VBOT  
Typ VBOT  
Max VBOT  
Units  
111  
110  
101  
100  
011  
010  
001  
000  
BOD Disabled  
1.7(2)  
2.5(2)  
4.1(2)  
1.8  
2.7  
4.3  
2.0(2)  
2.9(2)  
4.5(2)  
V
Reserved  
Notes: 1. VBOT may be below nominal minimum operating voltage for some devices. For  
devices where this is the case, the device is tested down to VCC = VBOT during the  
production test. This guarantees that a Brown-Out Reset will occur before VCC drops  
to a voltage where correct operation of the microcontroller is no longer guaranteed.  
The test is performed using BODLEVEL = 110 and BODLEVEL = 101 for  
ATmega48V/88V/168V, and BODLEVEL = 101 and BODLEVEL = 101 for  
ATmega48/88/168.  
2. Min/Max values applicable for ATmega48.  
Table 22. Brown-out Characteristics  
Symbol  
VHYST  
tBOD  
Parameter  
Min  
Typ  
Max  
Units  
mV  
Brown-out Detector Hysteresis  
Min Pulse Width on Brown-out Reset  
50  
ns  
When the BOD is enabled, and VCC decreases to a value below the trigger level (VBOT-  
in Figure 20), the Brown-out Reset is immediately activated. When VCC increases above  
the trigger level (VBOT+ in Figure 20), the delay counter starts the MCU after the Time-  
out period tTOUT has expired.  
43  
2545D–AVR–07/04  