欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATMEGA32L-8AUR 参数 Datasheet PDF下载

ATMEGA32L-8AUR图片预览
型号: ATMEGA32L-8AUR
PDF下载: 下载PDF文件 查看货源
内容描述: [RISC Microcontroller, 8-Bit, FLASH, AVR RISC CPU, 8MHz, CMOS, PQFP44, 10 X 10 MM, 1 MM HEIGHT, 0.80 MM PITCH, GREEN, PLASTIC, MS-026ACB, TQFP-44]
分类和应用: 闪存微控制器
文件页数/大小: 347 页 / 3171 K
品牌: ATMEL [ ATMEL ]
 浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第199页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第200页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第201页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第202页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第204页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第205页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第206页浏览型号ATMEGA32L-8AUR的Datasheet PDF文件第207页  
ATmega32(L)  
amplified value then becomes the analog input to the ADC. If single ended channels are  
used, the gain amplifier is bypassed altogether.  
The ADC is enabled by setting the ADC Enable bit, ADEN in ADCSRA. Voltage refer-  
ence and input channel selections will not go into effect until ADEN is set. The ADC  
does not consume power when ADEN is cleared, so it is recommended to switch off the  
ADC before entering power saving sleep modes.  
The ADC generates a 10-bit result which is presented in the ADC Data Registers,  
ADCH and ADCL. By default, the result is presented right adjusted, but can optionally  
be presented left adjusted by setting the ADLAR bit in ADMUX.  
If the result is left adjusted and no more than 8-bit precision is required, it is sufficient to  
read ADCH. Otherwise, ADCL must be read first, then ADCH, to ensure that the content  
of the Data Registers belongs to the same conversion. Once ADCL is read, ADC access  
to Data Registers is blocked. This means that if ADCL has been read, and a conversion  
completes before ADCH is read, neither register is updated and the result from the con-  
version is lost. When ADCH is read, ADC access to the ADCH and ADCL Registers is  
re-enabled.  
The ADC has its own interrupt which can be triggered when a conversion completes.  
When ADC access to the Data Registers is prohibited between reading of ADCH and  
ADCL, the interrupt will trigger even if the result is lost.  
Starting a Conversion  
A single conversion is started by writing a logical one to the ADC Start Conversion bit,  
ADSC. This bit stays high as long as the conversion is in progress and will be cleared by  
hardware when the conversion is completed. If a different data channel is selected while  
a conversion is in progress, the ADC will finish the current conversion before performing  
the channel change.  
Alternatively, a conversion can be triggered automatically by various sources. Auto Trig-  
gering is enabled by setting the ADC Auto Trigger Enable bit, ADATE in ADCSRA. The  
trigger source is selected by setting the ADC Trigger Select bits, ADTS in SFIOR (see  
description of the ADTS bits for a list of the trigger sources). When a positive edge  
occurs on the selected trigger signal, the ADC prescaler is reset and a conversion is  
started. This provides a method of starting conversions at fixed intervals. If the trigger  
signal still is set when the conversion completes, a new conversion will not be started. If  
another positive edge occurs on the trigger signal during conversion, the edge will be  
ignored. Note that an Interrupt Flag will be set even if the specific interrupt is disabled or  
the global interrupt enable bit in SREG is cleared. A conversion can thus be triggered  
without causing an interrupt. However, the Interrupt Flag must be cleared in order to trig-  
ger a new conversion at the next interrupt event.  
203  
2503J–AVR–10/06  
 复制成功!