欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATMEGA16U2-MUR 参数 Datasheet PDF下载

ATMEGA16U2-MUR图片预览
型号: ATMEGA16U2-MUR
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器具有ISP功能的Flash 8/16 / 32K Butes [8-bit Microcontroller with 8/16/32K Butes of ISP Flash]
分类和应用: 微控制器异步传输模式PCATM
文件页数/大小: 310 页 / 4432 K
品牌: ATMEL [ ATMEL ]
 浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第231页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第232页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第233页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第234页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第236页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第237页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第238页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第239页  
ATmega8U2/16U2/32U2  
page 237 for an example.  
23.8.7  
Setting the Boot Loader Lock Bits by SPM  
To set the Boot Loader Lock bits, write the desired data to R0, write “X0001001” to SPMCSR  
and execute SPM within four clock cycles after writing SPMCSR. The only accessible Lock bits  
are the Boot Lock bits that may prevent the Application and Boot Loader section from any soft-  
ware update by the MCU.  
Bit  
7
6
5
4
3
2
1
0
R0  
1
1
BLB12  
BLB11  
BLB02  
BLB01  
1
1
See Table 23-2 and Table 23-3 for how the different settings of the Boot Loader bits affect the  
Flash access.  
If bits 5..2 in R0 are cleared (zero), the corresponding Boot Lock bit will be programmed if an  
SPM instruction is executed within four cycles after BLBSET and SPMEN are set in SPMCSR.  
The Z-pointer is don’t care during this operation, but for future compatibility it is recommended to  
load the Z-pointer with 0x0001 (same as used for reading the lOck bits). For future compatibility it  
is also recommended to set bits 7, 6, 1, and 0 in R0 to “1” when writing the Lock bits. When pro-  
gramming the Lock bits the entire Flash can be read during the operation.  
23.8.8  
23.8.9  
EEPROM Write Prevents Writing to SPMCSR  
Note that an EEPROM write operation will block all software programming to Flash. Reading the  
Fuses and Lock bits from software will also be prevented during the EEPROM write operation. It  
is recommended that the user checks the status bit (EEPE) in the EECR Register and verifies  
that the bit is cleared before writing to the SPMCSR Register.  
Reading the Fuse and Lock Bits from Software  
It is possible to read both the Fuse and Lock bits from software. To read the Lock bits, load the  
Z-pointer with 0x0001 and set the BLBSET and SPMEN bits in SPMCSR. When an (E)LPM  
instruction is executed within three CPU cycles after the BLBSET and SPMEN bits are set in  
SPMCSR, the value of the Lock bits will be loaded in the destination register. The BLBSET and  
SPMEN bits will auto-clear upon completion of reading the Lock bits or if no (E)LPM instruction  
is executed within three CPU cycles or no SPM instruction is executed within four CPU cycles.  
When BLBSET and SPMEN are cleared, (E)LPM will work as described in the Instruction set  
Manual.  
Bit  
Rd  
7
6
5
4
3
2
1
0
BLB12  
BLB11  
BLB02  
BLB01  
LB2  
LB1  
The algorithm for reading the Fuse Low byte is similar to the one described above for reading  
the Lock bits. To read the Fuse Low byte, load the Z-pointer with 0x0000 and set the BLBSET  
and SPMEN bits in SPMCSR. When an (E)LPM instruction is executed within three cycles after  
the BLBSET and SPMEN bits are set in the SPMCSR, the value of the Fuse Low byte (FLB) will  
be loaded in the destination register as shown below. Refer to Table 25-5 on page 248 for a  
detailed description and mapping of the Fuse Low byte.  
Bit  
Rd  
7
6
5
4
3
2
1
0
FLB7  
FLB6  
FLB5  
FLB4  
FLB3  
FLB2  
FLB1  
FLB0  
Similarly, when reading the Fuse High byte, load 0x0003 in the Z-pointer. When an (E)LPM  
instruction is executed within three cycles after the BLBSET and SPMEN bits are set in the  
SPMCSR, the value of the Fuse High byte (FHB) will be loaded in the destination register as  
235  
7799D–AVR–11/10  