 浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第158页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第159页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第160页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第161页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第163页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第164页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第165页浏览型号ATMEGA16U2-MUR的Datasheet PDF文件第166页  
ATmega8U2/16U2/32U2  
Figure 18-5. Start Bit Sampling  
RxD  
IDLE  
START  
BIT 0  
Sample  
(U2X = 0)  
0
0
1
1
2
3
2
4
5
3
6
7
4
8
9
5
10  
11  
6
12  
13  
7
14  
15  
8
16  
1
1
2
3
Sample  
(U2X = 1)  
0
2
When the clock recovery logic detects a high (idle) to low (start) transition on the RxDn line, the  
start bit detection sequence is initiated. Let sample 1 denote the first zero-sample as shown in  
the figure. The clock recovery logic then uses samples 8, 9, and 10 for Normal mode, and sam-  
ples 4, 5, and 6 for Double Speed mode (indicated with sample numbers inside boxes on the  
figure), to decide if a valid start bit is received. If two or more of these three samples have logical  
high levels (the majority wins), the start bit is rejected as a noise spike and the Receiver starts  
looking for the next high to low-transition. If however, a valid start bit is detected, the clock recov-  
ery logic is synchronized and the data recovery can begin. The synchronization process is  
repeated for each start bit.  
18.8.2  
Asynchronous Data Recovery  
When the receiver clock is synchronized to the start bit, the data recovery can begin. The data  
recovery unit uses a state machine that has 16 states for each bit in Normal mode and eight  
states for each bit in Double Speed mode. Figure 18-6 shows the sampling of the data bits and  
the parity bit. Each of the samples is given a number that is equal to the state of the recovery  
unit.  
Figure 18-6. Sampling of Data and Parity Bit  
RxD  
BIT n  
Sample  
(U2X = 0)  
1
1
2
3
2
4
5
3
6
7
4
8
9
5
10  
11  
6
12  
13  
7
14  
15  
8
16  
1
1
Sample  
(U2X = 1)  
The decision of the logic level of the received bit is taken by doing a majority voting of the logic  
value to the three samples in the center of the received bit. The center samples are emphasized  
on the figure by having the sample number inside boxes. The majority voting process is done as  
follows: If two or all three samples have high levels, the received bit is registered to be a logic 1.  
If two or all three samples have low levels, the received bit is registered to be a logic 0. This  
majority voting process acts as a low pass filter for the incoming signal on the RxDn pin. The  
recovery process is then repeated until a complete frame is received. Including the first stop bit.  
Note that the Receiver only uses the first stop bit of a frame.  
Figure 18-7 shows the sampling of the stop bit and the earliest possible beginning of the start bit  
of the next frame.  
162  
7799D–AVR–11/10  