欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATMEGA128L-8AL 参数 Datasheet PDF下载

ATMEGA128L-8AL图片预览
型号: ATMEGA128L-8AL
PDF下载: 下载PDF文件 查看货源
内容描述: [RISC Microcontroller, 8-Bit, FLASH, 8MHz, CMOS, PQFP64, 14 X 14 MM, 1 MM HEIGHT, 0.80 MM PITCH, PLASTIC, MS-026AEB, TQFP-64]
分类和应用: 时钟微控制器外围集成电路
文件页数/大小: 391 页 / 6192 K
品牌: ATMEL [ ATMEL ]
 浏览型号ATMEGA128L-8AL的Datasheet PDF文件第116页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第117页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第118页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第119页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第121页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第122页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第123页浏览型号ATMEGA128L-8AL的Datasheet PDF文件第124页  
into the high byte Temporary Register (TEMP). When the CPU reads the ICRnH I/O location it  
will access the TEMP Register.  
The ICRn Register can only be written when using a Waveform Generation mode that utilizes  
the ICRn Register for defining the counter’s TOP value. In these cases the Waveform Genera-  
tion mode (WGMn3:0) bits must be set before the TOP value can be written to the ICRn  
Register. When writing the ICRn Register the high byte must be written to the ICRnH I/O location  
before the low byte is written to ICRnL.  
For more information on how to access the 16-bit registers refer to “Accessing 16-bit Registers”  
on page 115.  
Input Capture Pin  
Source  
The main trigger source for the Input Capture unit is the Input Capture Pin (ICPn).  
Timer/Counter1 can alternatively use the analog comparator output as trigger source for the  
Input Capture unit. The Analog Comparator is selected as trigger source by setting the analog  
Comparator Input Capture (ACIC) bit in the Analog Comparator Control and Status Register  
(ACSR). Be aware that changing trigger source can trigger a capture. The Input Capture flag  
must therefore be cleared after the change.  
Both the Input Capture Pin (ICPn) and the Analog Comparator output (ACO) inputs are sampled  
using the same technique as for the Tn pin (Figure 59 on page 143). The edge detector is also  
identical. However, when the noise canceler is enabled, additional logic is inserted before the  
edge detector, which increases the delay by four system clock cycles. Note that the input of the  
noise canceler and edge detector is always enabled unless the Timer/Counter is set in a Wave-  
form Generation mode that uses ICRn to define TOP.  
An Input Capture can be triggered by software by controlling the port of the ICPn pin.  
Noise Canceler  
The noise canceler improves noise immunity by using a simple digital filtering scheme. The  
noise canceler input is monitored over four samples, and all four must be equal for changing the  
output that in turn is used by the edge detector.  
The noise canceler is enabled by setting the Input Capture Noise Canceler (ICNCn) bit in  
Timer/Counter Control Register B (TCCRnB). When enabled the noise canceler introduces addi-  
tional four system clock cycles of delay from a change applied to the input, to the update of the  
ICRn Register. The noise canceler uses the system clock and is therefore not affected by the  
prescaler.  
Using the Input  
Capture Unit  
The main challenge when using the Input Capture unit is to assign enough processor capacity  
for handling the incoming events. The time between two events is critical. If the processor has  
not read the captured value in the ICRn Register before the next event occurs, the ICRn will be  
overwritten with a new value. In this case the result of the capture will be incorrect.  
When using the Input Capture interrupt, the ICRn Register should be read as early in the inter-  
rupt handler routine as possible. Even though the Input Capture interrupt has relatively high  
priority, the maximum interrupt response time is dependent on the maximum number of clock  
cycles it takes to handle any of the other interrupt requests.  
Using the Input Capture unit in any mode of operation when the TOP value (resolution) is  
actively changed during operation, is not recommended.  
Measurement of an external signal’s duty cycle requires that the trigger edge is changed after  
each capture. Changing the edge sensing must be done as early as possible after the ICRn  
Register has been read. After a change of the edge, the Input Capture flag (ICFn) must be  
cleared by software (writing a logical one to the I/O bit location). For measuring frequency only,  
the clearing of the ICFn flag is not required (if an interrupt handler is used).  
120  
ATmega128(L)  
2467P–AVR–08/07  
 复制成功!