 浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第278页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第279页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第280页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第281页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第283页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第284页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第285页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第286页  
26.5 Changing Channel or Reference Selection  
The MUXn and REFS1:0 bits in the ADMUX Register are single buffered through a temporary  
register to which the CPU has random access. This ensures that the channels and reference  
selection only takes place at a safe point during the conversion. The channel and reference  
selection is continuously updated until a conversion is started. Once the conversion starts, the  
channel and reference selection is locked to ensure a sufficient sampling time for the ADC. Con-  
tinuous updating resumes in the last ADC clock cycle before the conversion completes (ADIF in  
ADCSRA is set). Note that the conversion starts on the following rising ADC clock edge after  
ADSC is written. The user is thus advised not to write new channel or reference selection values  
to ADMUX until one ADC clock cycle after ADSC is written.  
If Auto Triggering is used, the exact time of the triggering event can be indeterministic. Special  
care must be taken when updating the ADMUX Register, in order to control which conversion  
will be affected by the new settings.  
If both ADATE and ADEN is written to one, an interrupt event can occur at any time. If the  
ADMUX Register is changed in this period, the user cannot tell if the next conversion is based  
on the old or the new settings. ADMUX can be safely updated in the following ways:  
1. When ADATE or ADEN is cleared.  
2. During conversion, minimum one ADC clock cycle after the trigger event.  
3. After a conversion, before the Interrupt Flag used as trigger source is cleared.  
When updating ADMUX in one of these conditions, the new settings will affect the next ADC  
conversion.  
Special care should be taken when changing differential channels. Once a differential channel  
has been selected, the stage may take as much as 125 µs to stabilize to the new value. Thus  
conversions should not be started within the first 125 µs after selecting a new differential chan-  
nel. Alternatively, conversion results obtained within this period should be discarded.  
The same settling time should be observed for the first differential conversion after changing  
ADC reference (by changing the REFS1:0 bits in ADMUX).  
26.5.1  
ADC Input Channels  
When changing channel selections, the user should observe the following guidelines to ensure  
that the correct channel is selected:  
In Single Conversion mode, always select the channel before starting the conversion. The chan-  
nel selection may be changed one ADC clock cycle after writing one to ADSC. However, the  
simplest method is to wait for the conversion to complete before changing the channel selection.  
In Free Running mode, always select the channel before starting the first conversion. The chan-  
nel selection may be changed one ADC clock cycle after writing one to ADSC. However, the  
simplest method is to wait for the first conversion to complete, and then change the channel  
selection. Since the next conversion has already started automatically, the next result will reflect  
the previous channel selection. Subsequent conversions will reflect the new channel selection.  
When switching to a differential gain channel, the first conversion result may have a poor accu-  
racy due to the required settling time for the automatic offset cancellation circuitry. The user  
should preferably disregard the first conversion result.  
282  
ATmega640/1280/1281/2560/2561  
2549L–AVR–08/07  