 浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第215页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第216页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第217页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第218页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第220页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第221页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第222页浏览型号ATMEGA2560-16AU-SL383的Datasheet PDF文件第223页  
ATmega640/1280/1281/2560/2561  
The UPEn bit is set if the next character that can be read from the receive buffer had a Parity  
Error when received and the Parity Checking was enabled at that point (UPMn1 = 1). This bit is  
valid until the receive buffer (UDRn) is read.  
22.6.6  
22.6.7  
Disabling the Receiver  
In contrast to the Transmitter, disabling of the Receiver will be immediate. Data from ongoing  
receptions will therefore be lost. When disabled (i.e., the RXENn is set to zero) the Receiver will  
no longer override the normal function of the RxDn port pin. The Receiver buffer FIFO will be  
flushed when the Receiver is disabled. Remaining data in the buffer will be lost  
Flushing the Receive Buffer  
The receiver buffer FIFO will be flushed when the Receiver is disabled, i.e., the buffer will be  
emptied of its contents. Unread data will be lost. If the buffer has to be flushed during normal  
operation, due to for instance an error condition, read the UDRn I/O location until the RXCn Flag  
is cleared. The following code example shows how to flush the receive buffer.  
Assembly Code Example(1)  
USART_Flush:  
sbis UCSRnA, RXCn  
ret  
in  
r16, UDRn  
rjmp USART_Flush  
C Code Example(1)  
void USART_Flush( void )  
{
unsigned char dummy;  
while ( UCSRnA & (1<<RXCn) ) dummy = UDRn;  
}
Note:  
1. See “About Code Examples” on page 10.  
22.7 Asynchronous Data Reception  
The USART includes a clock recovery and a data recovery unit for handling asynchronous data  
reception. The clock recovery logic is used for synchronizing the internally generated baud rate  
clock to the incoming asynchronous serial frames at the RxDn pin. The data recovery logic sam-  
ples and low pass filters each incoming bit, thereby improving the noise immunity of the  
Receiver. The asynchronous reception operational range depends on the accuracy of the inter-  
nal baud rate clock, the rate of the incoming frames, and the frame size in number of bits.  
22.7.1  
Asynchronous Clock Recovery  
The clock recovery logic synchronizes internal clock to the incoming serial frames. Figure 22-5  
illustrates the sampling process of the start bit of an incoming frame. The sample rate is 16 times  
the baud rate for Normal mode, and eight times the baud rate for Double Speed mode. The hor-  
izontal arrows illustrate the synchronization variation due to the sampling process. Note the  
larger time variation when using the Double Speed mode (U2Xn = 1) of operation. Samples  
denoted zero are samples done when the RxDn line is idle (i.e., no communication activity).  