 浏览型号AT90PWM3B-16SU的Datasheet PDF文件第100页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第101页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第102页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第103页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第105页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第106页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第107页浏览型号AT90PWM3B-16SU的Datasheet PDF文件第108页  
The Input Capture Register can capture the Timer/Counter value at a given external (edge trig-  
gered) event on either the Input Capture pin (ICPn). The Input Capture unit includes a digital  
filtering unit (Noise Canceler) for reducing the chance of capturing noise spikes.  
The TOP value, or maximum Timer/Counter value, can in some modes of operation be defined  
by either the OCRnA Register, the ICRn Register, or by a set of fixed values. When using  
OCRnA as TOP value in a PWM mode, the OCRnA Register can not be used for generating a  
PWM output. However, the TOP value will in this case be double buffered allowing the TOP  
value to be changed in run time. If a fixed TOP value is required, the ICRn Register can be used  
as an alternative, freeing the OCRnA to be used as PWM output.  
15.1.2  
Definitions  
The following definitions are used extensively throughout the section:  
Table 15-1.  
BOTTOM  
The counter reaches the BOTTOM when it becomes 0x0000.  
MAX  
The counter reaches its MAXimum when it becomes 0xFFFF (decimal 65535).  
The counter reaches the TOP when it becomes equal to the highest value in the count  
sequence. The TOP value can be assigned to be one of the fixed values: 0x00FF, 0x01FF,  
or 0x03FF, or to the value stored in the OCRnA or ICRn Register. The assignment is  
dependent of the mode of operation.  
TOP  
15.2 Accessing 16-bit Registers  
The TCNTn, OCRnx, and ICRn are 16-bit registers that can be accessed by the AVR CPU via  
the 8-bit data bus. The 16-bit register must be byte accessed using two read or write operations.  
Each 16-bit timer has a single 8-bit register for temporary storing of the high byte of the 16-bit  
access. The same temporary register is shared between all 16-bit registers within each 16-bit  
timer. Accessing the low byte triggers the 16-bit read or write operation. When the low byte of a  
16-bit register is written by the CPU, the high byte stored in the temporary register, and the low  
byte written are both copied into the 16-bit register in the same clock cycle. When the low byte of  
a 16-bit register is read by the CPU, the high byte of the 16-bit register is copied into the tempo-  
rary register in the same clock cycle as the low byte is read.  
Not all 16-bit accesses uses the temporary register for the high byte. Reading the OCRnx 16-bit  
registers does not involve using the temporary register.  
To do a 16-bit write, the high byte must be written before the low byte. For a 16-bit read, the low  
byte must be read before the high byte.  
The following code examples show how to access the 16-bit Timer Registers assuming that no  
interrupts updates the temporary register. The same principle can be used directly for accessing  
the OCRnx and ICRn Registers. Note that when using “C”, the compiler handles the 16-bit  
access.  