Table 4. SPCRSPI Control Register  
SPCR Address = D5H  
Reset Value = 0000 01XXB  
SPIE  
7
SPE  
6
DORD  
5
MSTR  
4
CPOL  
3
CPHA  
2
SPR1  
1
SPR0  
0
Bit  
Symbol  
Function  
SPIE  
SPI Interrupt Enable. This bit, in conjunction with the ES bit in the IE register, enables SPI interrupts: SPIE = 1 and ES  
= 1 enable SPI interrupts. SPIE = 0 disables SPI interrupts.  
SPE  
SPI Enable. SPI = 1 enables the SPI channel and connects SS, MOSI, MISO and SCK to pins P1.4, P1.5, P1.6, and  
P1.7. SPI = 0 disables the SPI channel.  
DORD  
MSTR  
CPOL  
Data Order. DORD = 1 selects LSB first data transmission. DORD = 0 selects MSB first data transmission.  
Master/Slave Select. MSTR = 1 selects Master SPI mode. MSTR = 0 selects Slave SPI mode.  
Clock Polarity. When CPOL = 1, SCK is high when idle. When CPOL = 0, SCK of the master device is low when not  
transmitting. Please refer to figure on SPI Clock Phase and Polarity Control.  
CPHA  
Clock Phase. The CPHA bit together with the CPOL bit controls the clock and data relationship between master and  
slave. Please refer to figure on SPI Clock Phase and Polarity Control.  
SPR0  
SPR1  
SPI Clock Rate Select. These two bits control the SCK rate of the device configured as master. SPR1 and SPR0 have  
no effect on the slave. The relationship between SCK and the oscillator frequency, FOSC., is as follows:  
SPR1SPR0SCK = FOSC. divided by  
0
0
1
1
0
1
0
4
16  
64  
1 128  
Table 5. SPSRSPI Status Register Data Memory - RAM  
SPSR Address = AAH  
Reset Value = 00XX XXXXB  
SPIF  
7
WCOL  
6
5
4
3
2
1
0
Bit  
Symbol  
Function  
SPIF  
SPI Interrupt Flag. When a serial transfer is complete, the SPIF bit is set and an interrupt is generated if SPIE = 1 and  
ES = 1. The SPIF bit is cleared by reading the SPI status register with SPIF and WCOL bits set, and then accessing  
the SPI data register.  
WCOL  
Write Collision Flag. The WCOL bit is set if the SPI data register is written during a data transfer. During data transfer,  
the result of reading the SPDR register may be incorrect, and writing to it has no effect. The WCOL bit (and the SPIF  
bit) are cleared by reading the SPI status register with SPIF and WCOL set, and then accessing the SPI data register.  
Table 6. SPDRSPI Data Register  
SPDR Address = 86H  
Reset Value = unchanged  
SPD7  
7
SPD6  
6
SPD5  
5
SPD4  
4
SPD3  
3
SPD2  
2
SPD1  
1
SPD0  
0
Bit  
AT89S53  