欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT89S52-33PC 参数 Datasheet PDF下载

AT89S52-33PC图片预览
型号: AT89S52-33PC
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器具有8K字节的系统内可编程闪存 [8-bit Microcontroller with 8K Bytes In-System Programmable Flash]
分类和应用: 闪存微控制器
文件页数/大小: 30 页 / 231 K
品牌: ATMEL [ ATMEL CORPORATION ]
 浏览型号AT89S52-33PC的Datasheet PDF文件第6页浏览型号AT89S52-33PC的Datasheet PDF文件第7页浏览型号AT89S52-33PC的Datasheet PDF文件第8页浏览型号AT89S52-33PC的Datasheet PDF文件第9页浏览型号AT89S52-33PC的Datasheet PDF文件第11页浏览型号AT89S52-33PC的Datasheet PDF文件第12页浏览型号AT89S52-33PC的Datasheet PDF文件第13页浏览型号AT89S52-33PC的Datasheet PDF文件第14页  
In the Counter function, the register is incremented in
response to a 1-to-0 transition at its corresponding external
input pin, T2. In this function, the external input is sampled
during S5P2 of every machine cycle. When the samples
show a high in one cycle and a low in the next cycle, the
count is incremented. The new count value appears in the
register during S3P1 of the cycle following the one in which
the transition was detected. Since two machine cycles (24
oscillator periods) are required to recognize a 1-to-0 transi-
tion, the maximum count rate is 1/24 of the oscillator fre-
quency. To ensure that a given level is sampled at least
once before it changes, the level should be held for at least
one full machine cycle.
This bit can then be used to generate an interrupt. If
EXEN2 = 1, Timer 2 performs the same operation, but a 1-
to-0 transition at external input T2EX also causes the
current value in TH2 and TL2 to be captured into RCAP2H
and RCAP2L, respectively. In addition, the transition at
T2EX causes bit EXF2 in T2CON to be set. The EXF2 bit,
like TF2, can generate an interrupt. The capture mode is
illustrated in Figure 5.
Auto-reload (Up or Down Counter)
Timer 2 can be programmed to count up or down when
configured in its 16-bit auto-reload mode. This feature is
invoked by the DCEN (Down Counter Enable) bit located in
the SFR T2MOD (see Table 4). Upon reset, the DCEN bit
is set to 0 so that timer 2 will default to count up. When
DCEN is set, Timer 2 can count up or down, depending on
the value of the T2EX pin.
Capture Mode
In the capture mode, two options are selected by bit
EXEN2 in T2CON. If EXEN2 = 0, Timer 2 is a 16-bit timer
or counter which upon overflow sets bit TF2 in T2CON.
Figure 5.
Timer in Capture Mode
OSC
÷12
C/T2 = 0
TH2
CONTROL
C/T2 = 1
T2 PIN
TRANSITION
DETECTOR
T2EX PIN
CONTROL
EXEN2
EXF2
TR2
CAPTURE
TL2
TF2
OVERFLOW
RCAP2H RCAP2L
TIMER 2
INTERRUPT
Figure 6 shows Timer 2 automatically counting up when
DCEN=0. In this mode, two options are selected by bit
EXEN2 in T2CON. If EXEN2 = 0, Timer 2 counts up to
0FFFFH and then sets the TF2 bit upon overflow. The
overflow also causes the timer registers to be reloaded with
the 16-bit value in RCAP2H and RCAP2L. The values in
Timer in Capture ModeRCAP2H and RCAP2L are preset
by software. If EXEN2 = 1, a 16-bit reload can be triggered
either by an overflow or by a 1-to-0 transition at external
input T2EX. This transition also sets the EXF2 bit. Both the
TF2 and EXF2 bits can generate an interrupt if enabled.
Setting the DCEN bit enables Timer 2 to count up or down,
as shown in Figure 6. In this mode, the T2EX pin controls
the direction of the count. A logic 1 at T2EX makes Timer 2
count up. The timer will overflow at 0FFFFH and set the
TF2 bit. This overflow also causes the 16-bit value in
RCAP2H and RCAP2L to be reloaded into the timer regis-
ters, TH2 and TL2, respectively.
A logic 0 at T2EX makes Timer 2 count down. The timer
underflows when TH2 and TL2 equal the values stored in
RCAP2H and RCAP2L. The underflow sets the TF2 bit and
causes 0FFFFH to be reloaded into the timer registers.
The EXF2 bit toggles whenever Timer 2 overflows or
underflows and can be used as a 17th bit of resolution. In
this operating mode, EXF2 does not flag an interrupt.
10