欢迎访问ic37.com |
会员登录 免费注册
发布采购

AT45DB321D-TU 参数 Datasheet PDF下载

AT45DB321D-TU图片预览
型号: AT45DB321D-TU
PDF下载: 下载PDF文件 查看货源
内容描述: 32兆位2.7伏的DataFlash [32-megabit 2.7-volt DataFlash]
分类和应用:
文件页数/大小: 55 页 / 1471 K
品牌: ATMEL [ ATMEL ]
 浏览型号AT45DB321D-TU的Datasheet PDF文件第12页浏览型号AT45DB321D-TU的Datasheet PDF文件第13页浏览型号AT45DB321D-TU的Datasheet PDF文件第14页浏览型号AT45DB321D-TU的Datasheet PDF文件第15页浏览型号AT45DB321D-TU的Datasheet PDF文件第17页浏览型号AT45DB321D-TU的Datasheet PDF文件第18页浏览型号AT45DB321D-TU的Datasheet PDF文件第19页浏览型号AT45DB321D-TU的Datasheet PDF文件第20页  
9.1.2  
Program Sector Protection Register Command  
Once the Sector Protection Register has been erased, it can be reprogrammed using the Pro-  
gram Sector Protection Register command.  
To program the Sector Protection Register, the CS pin must first be asserted and the appropri-  
ate 4-byte opcode sequence must be clocked into the device via the SI pin. The 4-byte opcode  
sequence must start with 3DH and be followed by 2AH, 7FH, and FCH. After the last bit of the  
opcode sequence has been clocked into the device, the data for the contents of the Sector Pro-  
tection Register must be clocked in. As described in Section 9.1, the Sector Protection Register  
contains 64 bytes of data, so 64 bytes must be clocked into the device. The first byte of data cor-  
responds to sector 0, the second byte corresponds to sector 1, and so on with the last byte of  
data corresponding to sector 63.  
After the last data byte has been clocked in, the CS pin must be deasserted to initiate the inter-  
nally self-timed program cycle. The programming of the Sector Protection Register should take  
place in a time of tP, during which time the Status Register will indicate that the device is busy. If  
the device is powered-down during the program cycle, then the contents of the Sector Protection  
Register cannot be guaranteed.  
If the proper number of data bytes is not clocked in before the CS pin is deasserted, then the  
protection status of the sectors corresponding to the bytes not clocked in can not be guaranteed.  
For example, if only the first two bytes are clocked in instead of the complete 62 bytes, then the  
protection status of the last 62 sectors cannot be guaranteed. Furthermore, if more than  
64 bytes of data is clocked into the device, then the data will wrap back around to the beginning  
of the register. For instance, if 65 bytes of data are clocked in, then the 65th byte will be stored at  
byte location 0 of the Sector Protection Register.  
If a value other than 00H or FFH is clocked into a byte location of the Sector Protection Register,  
then the protection status of the sector corresponding to that byte location cannot be guaran-  
teed. For example, if a value of 17H is clocked into byte location 2 of the Sector Protection  
Register, then the protection status of sector 2 cannot be guaranteed.  
The Sector Protection Register can be reprogrammed while the sector protection enabled or dis-  
abled. Being able to reprogram the Sector Protection Register with the sector protection enabled  
allows the user to temporarily disable the sector protection to an individual sector rather than dis-  
abling sector protection completely.  
The Program Sector Protection Register command utilizes the internal SRAM buffer 1 for pro-  
cessing. Therefore, the contents of the buffer 1 will be altered from its previous state when this  
command is issued.  
Command  
Byte 1  
Byte 2  
Byte 3  
Byte 4  
Program Sector Protection Register  
3DH  
2AH  
7FH  
FCH  
Figure 9-3. Program Sector Protection Register  
CS  
Opcode  
Byte 1  
Opcode  
Byte 2  
Opcode  
Byte 3  
Opcode  
Byte 4  
Data Byte  
n
Data Byte  
n + 1  
Data Byte  
n + 63  
SI  
Each transition  
represents 8 bits  
16  
AT45DB321D [Preliminary]  
3597H–DFLASH–02/07  
 复制成功!