欢迎访问ic37.com |
会员登录 免费注册
发布采购

90USB82-16MU 参数 Datasheet PDF下载

90USB82-16MU图片预览
型号: 90USB82-16MU
PDF下载: 下载PDF文件 查看货源
内容描述: 8位微控制器具有ISP功能的Flash 8 / 16K字节 [8-bit Microcontroller with 8/16K Bytes of ISP Flash]
分类和应用: 微控制器和处理器外围集成电路异步传输模式ATM时钟
文件页数/大小: 306 页 / 2299 K
品牌: ATMEL [ ATMEL ]
 浏览型号90USB82-16MU的Datasheet PDF文件第232页浏览型号90USB82-16MU的Datasheet PDF文件第233页浏览型号90USB82-16MU的Datasheet PDF文件第234页浏览型号90USB82-16MU的Datasheet PDF文件第235页浏览型号90USB82-16MU的Datasheet PDF文件第237页浏览型号90USB82-16MU的Datasheet PDF文件第238页浏览型号90USB82-16MU的Datasheet PDF文件第239页浏览型号90USB82-16MU的Datasheet PDF文件第240页  
is executed within three CPU cycles or no SPM instruction is executed within four CPU cycles.  
When BLBSET and SPMEN are cleared, (E)LPM will work as described in the Instruction set  
Manual.  
Bit  
Rd  
7
6
5
4
3
2
1
0
BLB12  
BLB11  
BLB02  
BLB01  
LB2  
LB1  
The algorithm for reading the Fuse Low byte is similar to the one described above for reading  
the Lock bits. To read the Fuse Low byte, load the Z-pointer with 0x0000 and set the BLBSET  
and SPMEN bits in SPMCSR. When an (E)LPM instruction is executed within three cycles after  
the BLBSET and SPMEN bits are set in the SPMCSR, the value of the Fuse Low byte (FLB) will  
be loaded in the destination register as shown below. Refer to Table 25-5 on page 245 for a  
detailed description and mapping of the Fuse Low byte.  
Bit  
Rd  
7
6
5
4
3
2
1
0
FLB7  
FLB6  
FLB5  
FLB4  
FLB3  
FLB2  
FLB1  
FLB0  
Similarly, when reading the Fuse High byte, load 0x0003 in the Z-pointer. When an (E)LPM  
instruction is executed within three cycles after the BLBSET and SPMEN bits are set in the  
SPMCSR, the value of the Fuse High byte (FHB) will be loaded in the destination register as  
shown below. Refer to Table 25-4 on page 245 for detailed description and mapping of the Fuse  
High byte.  
Bit  
Rd  
7
6
5
4
3
2
1
0
FHB7  
FHB6  
FHB5  
FHB4  
FHB3  
FHB2  
FHB1  
FHB0  
When reading the Extended Fuse byte, load 0x0002 in the Z-pointer. When an (E)LPM instruc-  
tion is executed within three cycles after the BLBSET and SPMEN bits are set in the SPMCSR,  
the value of the Extended Fuse byte (EFB) will be loaded in the destination register as shown  
below. Refer to Table 25-3 on page 244 for detailed description and mapping of the Extended  
Fuse byte.  
Bit  
Rd  
7
6
5
4
3
2
1
0
EFB2  
EFB1  
EFB0  
Fuse and Lock bits that are programmed, will be read as zero. Fuse and Lock bits that are  
unprogrammed, will be read as one.  
23.7.10 Reading the Signature Row from Software  
To read the Signature Row from software, load the Z-pointer with the signature byte address  
given in Table 23-6 on page 236 and set the SIGRD and SPMEN bits in SPMCSR. When an  
LPM instruction is executed within three CPU cycles after the SIGRD and SPMEN bits are set in  
SPMCSR, the signature byte value will be loaded in the destination register. The SIGRD and  
SPMEN bits will auto-clear upon completion of reading the Signature Row Lock bits or if no LPM  
instruction is executed within three CPU cycles. When SIGRD and SPMEN are cleared, LPM will  
work as described in the Instruction set Manual.  
Table 23-6. Signature Row Addressing  
Signature Byte  
Z-Pointer Address  
0x0000  
Device Signature Byte 1  
Device Signature Byte 2  
Device Signature Byte 3  
RC Oscillator Calibration Byte  
0x0002  
0x0004  
0x0001  
236  
AT90USB82/162  
7707D–AVR–07/08  
 复制成功!