Using the Input Capture unit in any mode of operation when the TOP value (resolution) is  
actively changed during operation, is not recommended.  
Measurement of an external signal’s duty cycle requires that the trigger edge is changed after  
each capture. Changing the edge sensing must be done as early as possible after the ICRn  
Register has been read. After a change of the edge, the Input Capture Flag (ICFn) must be  
cleared by software (writing a logical one to the I/O bit location). For measuring frequency only,  
the clearing of the ICFn Flag is not required (if an interrupt handler is used).  
15.6 Output Compare Units  
The 16-bit comparator continuously compares TCNTn with the Output Compare Register  
(OCRnx). If TCNT equals OCRnx the comparator signals a match. A match will set the Output  
Compare Flag (OCFnx) at the next timer clock cycle. If enabled (OCIEnx = 1), the Output Com-  
pare Flag generates an Output Compare interrupt. The OCFnx Flag is automatically cleared  
when the interrupt is executed. Alternatively the OCFnx Flag can be cleared by software by writ-  
ing a logical one to its I/O bit location. The Waveform Generator uses the match signal to  
generate an output according to operating mode set by the Waveform Generation mode  
(WGMn3:0) bits and Compare Output mode (COMnx1:0) bits. The TOP and BOTTOM signals  
are used by the Waveform Generator for handling the special cases of the extreme values in  
some modes of operation (See “Modes of Operation” on page 119.)  
A special feature of Output Compare unit A allows it to define the Timer/Counter TOP value (i.e.,  
counter resolution). In addition to the counter resolution, the TOP value defines the period time  
for waveforms generated by the Waveform Generator.  
Figure 15-4 shows a block diagram of the Output Compare unit. The small “n” in the register and  
bit names indicates the device number (n = n for Timer/Counter n), and the “x” indicates Output  
Compare unit (A/B/C). The elements of the block diagram that are not directly a part of the Out-  
put Compare unit are gray shaded.  
Figure 15-4. Output Compare Unit, Block Diagram  
DATA BUS (8-bit)  
TEMP (8-bit)  
OCRnxH Buf. (8-bit)  
OCRnxL Buf. (8-bit)  
TCNTnH (8-bit)  
TCNTnL (8-bit)  
OCRnx Buffer (16-bit Register)  
TCNTn (16-bit Counter)  
OCRnxH (8-bit)  
OCRnxL (8-bit)  
OCRnx (16-bit Register)  
= (16-bit Comparator )  
OCFnx (Int.Req.)  
TOP  
OCnx  
Waveform Generator  
BOTTOM  
WGMn3:0  
COMnx1:0  
116  
AT90USB82/162  
7707D–AVR–07/08  
 复制成功!