欢迎访问ic37.com |
会员登录 免费注册
发布采购

85C51SND3BX01 参数 Datasheet PDF下载

85C51SND3BX01图片预览
型号: 85C51SND3BX01
PDF下载: 下载PDF文件 查看货源
内容描述: 单芯片数字音频解码器 - 编码器与USB 2.0接口 [Single-Chip Digital Audio Decoder - Encoder with USB 2.0 Interface]
分类和应用: 解码器编码器
文件页数/大小: 263 页 / 3620 K
品牌: ATMEL [ ATMEL ]
 浏览型号85C51SND3BX01的Datasheet PDF文件第76页浏览型号85C51SND3BX01的Datasheet PDF文件第77页浏览型号85C51SND3BX01的Datasheet PDF文件第78页浏览型号85C51SND3BX01的Datasheet PDF文件第79页浏览型号85C51SND3BX01的Datasheet PDF文件第81页浏览型号85C51SND3BX01的Datasheet PDF文件第82页浏览型号85C51SND3BX01的Datasheet PDF文件第83页浏览型号85C51SND3BX01的Datasheet PDF文件第84页  
selected as source, the null device is always ready and sends the data (2 bytes) of the  
initialized CRC value MSB first.  
Channel Priority  
The Data Flow Controller bandwidth is shared between Channel 0 and Channel 1. In  
case both channels are ready to transfer data, bus bandwidth is shared on a byte by  
byte basis.  
In order to allocate maximum bandwidth to a specified channel, priority can be assigned  
to channel 0 or to channel 1 by setting the DFPRIO1:0 bits in DFCON according to  
Table 93.  
DFPRIO1:0 can be modified at any time while transfer is on-going or not.  
Table 93. Channel Priority Assignment  
DFPRIO1  
DFPRIO0 Assignment Description  
0
0
1
1
0
1
0
1
No priority assigned: channel 0 & channel 1 have same priority.  
Priority assigned to channel 0.  
Priority assigned to channel 1.  
Reserved, do not set both bits.  
Data Flow Status  
Data Flow Abort  
An on-going data flow transfer is reported to user using the bits DFBSY0 and DFBSY1  
in DFCSTA. These bits are set as soon as the DFD has been fully written to the corre-  
sponding channel and cleared at the end of transfer or abort.  
Source peripheral and destination peripheral status is dynamically reported by SRDY0,  
DRDY0, SRDY1, DRDY1 ready flags in DFCSTA.  
The DFC allows asynchronous abort of any on-going flow. Abort is controlled by the  
DFABT0, DFABT1, the Channel Data Flow Abort control bits in DFCCON and DFABTM  
the Data Flow Abort Mode control bit in DFCON.  
Setting DFABT0 or DFABT1 while a flow transfer is on-going triggers on the correspond-  
ing channel an immediate or delayed abort depending on the DFABTM value. DFABTM  
cleared triggers an immediate abort where data flow transfer is stopped at the end of the  
on-going byte transfer while DFABTM set triggers a delayed abort where data flow  
transfer is stopped at the end of the on-going data packet transfer. Above abort modes  
set the End of Flow interrupt flag of the corresponding channel.  
Setting DFABT0 or DFABT1 while a DFD is under writing will reset the DFD content of  
the corresponding channel. Such abort does not set the End of Flow interrupt flag of the  
corresponding channel.  
Abort Status  
In case a data flow transfer is aborted, the remaining number of data packets to be  
transmitted can be retrieved by reading two bytes with MSB first from the data flow  
descriptor register DFD0 (channel 0) or to DFD1 (channel 1). This feature is of interest  
in case of logical data flow management over a physical channel.  
Note:  
In case of immediate abort, returned value is not significant since part of the DP is  
already transmitted.  
80  
AT85C51SND3Bx  
7632A–MP3–03/06  
 复制成功!