 浏览型号85C51SND3B1N-UL的Datasheet PDF文件第75页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第76页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第77页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第78页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第80页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第81页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第82页浏览型号85C51SND3B1N-UL的Datasheet PDF文件第83页  
AT85C51SND3Bx  
Table 92 shows the different peripherals (source or destination) ID number. These num-  
bers are used to program the SID and the DID in the DFD.  
Table 91. Data Flow Descriptor Content  
Byte  
Byte  
Number  
Mnemonic Description  
Source Identifier  
0
1
SID  
DID  
See Table 92 for peripheral ID number.  
Destination Identifier  
See Table 92 for peripheral ID number.  
Data Packet Size  
Decimal value giving the packet size as 2DPS. DPS takes value from 0 (1-byte  
packet size) to 13 (8192-byte packet size).  
2
DPS  
Packet size is limited to 8192 bytes in case of DPS value greater than 13  
3
4
DFSH  
DFSL  
Data Flow Size  
16-bit wide data leading to data flow size from 1 to 216- 1 data packets.  
Writing 0x0000 to this field enables continuous data flow.  
Table 92. Peripheral ID Number  
ID Number  
Peripheral  
0
C51 RAM  
1
USB Controller  
Audio Controller 1  
Audio Controller 2  
PSI Controller  
SPI Controller  
SIO Controller  
Nand Flash Controller  
MMC/SD Controller  
Reserved  
2
3
4
5
6
7
8
9 n 14  
15  
Null Device  
CRC Processor  
In order to verify integrity of data transferred through the DFC, a CRC calculation can be  
enabled using DFCRCEN bit in DFCON. It consists in a 16-bit CRC which is the remain-  
der after transfer data (MSB first) is divided by G(X). Polynomial formula is: G(X) = X16  
+
X15 + X2 + 1.  
CRC16 operates on channel 0 only.  
After an hardware reset, the CRC value is 0x0000 but can be set to any initial value by  
writing two bytes(1) (MSB first) in the DFCRC register.  
At the end of the data flow transfer(2), CRC is available to user by reading two bytes(1)  
(MSB first) from the DFCRC register.  
Notes: 1. This double write or read sequence can be reset by clearing the CRCEN bit.  
2. The CRC value is not reset at start-up of a new data transfer.  
Null Device  
The null device is used to allow CRC calculation on some data transfer (see  
Section “CRC Processor”). When selected as destination, the null device is always  
ready and simply acknowledges and discards data coming from the source. When  
79  
7632A–MP3–03/06  
 复制成功!