Electrical Characteristics
Absolute Maximum Ratings
*NOTICE:
Stresses beyond those listed under "Absolute Maxi-
mum Ratings” may cause permanent damage to the
device. This is a stress rating only and functional oper-
ation of the device at these or any other conditions
beyond those indicated in the operational sections of
this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
Supply Voltage (VCC - GND):.............................- 0.5V to 7.0V
Input or Output Voltage Applied:.(GND - 0.3V) to (Vcc + 0.3V)
Storage Temperature:.................................. - 65 °C to + 150 °C
DC Parameters
Table 3. DC Test Conditions
TA = – 55°C to + 125°C; Vss = 0V; Vcc = 4.5V to 5.5V
Parameter
Description
M M67204H-30
M M67204H-15
Unit
Value
Operating
supply current
(1)
ICCOP
110
120
5
mA
Max
Standby
supply current
(2)
ICCSB
5
mA
µA
Max
Max
Power down
current
(3)
ICCPD
400
400
ILI (4)
Input leakage current
Output leakage current
Input low voltage
1
1
µA
µA
V
Max
Max
Max
Min
ILO (5)
(6)
VIL
0.8
2.2
0.4
2.4
8
VIH(6)
Input high voltage
Output low voltage
Output high voltage
Input capacitance
Output capacitance
V
(7)
VOL
V
Max
Min
VOH (7)
V
(8)
C IN
pF
pF
Max
Max
C OUT (8)
8
1.
2.
3.
4.
5.
6.
7.
8.
Icc measurements are made with outputs open.
R = W = RS = FL/RT = VIH.
All input = Vcc.
0.4 ≤ Vin ≤ Vcc.
R = VIH, 0.4 ≤ VOUT ≤ VCC.
VIH max = Vcc + 0.3V. VIL min = -0.3V or -1V pulse width 50 ns. For XI input, VIH= 2.8V
Vcc min, IOL = 8 mA, IOH = -2 mA.
Guaranteed but not tested.
10
M67204H