DC Parameters
Parameter
Description
Minimum
Typical
Maximum
Unit
IIX (1)
Input leakage current
-1
–
1
µA
Output leakage
current
IOZ(1)
-1
–
–
–
–
1
2
µA
µA
µA
Input Leakage
Current
IIH(2) at 5.5V
Output Leakage
Current
IOZH(2) at 5.5V
–
1.5
VOL(3)
VOH(4)
Output low voltage
Output high voltage
–
–
–
0.4
–
V
V
2.4
1.
2.
3.
GND < VIN < VCC, GND < VOUT < VCC Output Disabled.
VIN = 5.5V, VOUT = 5.5V, Output Disabled.
V
CC min. IOL = 6 mA
4.
VCC min. IOH = -4 mA.
Consumption
TAVAV/TAVAW
Test Condition
Symbol
Description
AT60142FT-17
AT60142FT-15
Unit
Value
Standby Supply
Current
(1)
ICCSB
–
–
2
2.5
2
mA
max
max
Standby Supply
Current
(2)
ICCSB1
1.8
mA
mA
15 ns
17 ns
25 ns
50 ns
-
180
170
150
75
Dynamic
Operating
Current
170
150
75
ICCOP(3) Read
max
max
10
10
1 µs
15 ns
17 ns
25 ns
50 ns
-
150
145
130
120
100
Dynamic
Operating
Current
145
130
120
100
ICCOP(4) Write
mA
1 µs
1.
2.
3.
4.
CS >VIH
CS > VCC - 0.3V
F = 1/TAVAV, Iout = 0 mA, WE = OE = VIH, VIN = GND/VCC, VCC max.
F = 1/TAVAW, Iout = 0 mA, WE = VIL, OE = VIH , VIN = GND/VCC, VCC max.
5
AT60142FT
7726A–AERO–07/07