欢迎访问ic37.com |
会员登录 免费注册
发布采购

2M30 参数 Datasheet PDF下载

2M30图片预览
型号: 2M30
PDF下载: 下载PDF文件 查看货源
内容描述: Camera Link的Areascan相机 [Camera Link Areascan Cameras]
分类和应用:
文件页数/大小: 24 页 / 451 K
品牌: ATMEL [ ATMEL CORPORATION ]
 浏览型号2M30的Datasheet PDF文件第5页浏览型号2M30的Datasheet PDF文件第6页浏览型号2M30的Datasheet PDF文件第7页浏览型号2M30的Datasheet PDF文件第8页浏览型号2M30的Datasheet PDF文件第10页浏览型号2M30的Datasheet PDF文件第11页浏览型号2M30的Datasheet PDF文件第12页浏览型号2M30的Datasheet PDF文件第13页  
[Preliminary] ATMOS -2M60/2M30
• Readout of frame N. The readout data is forwarded to the Camera Link interface (FVAL
active) starting with the first line
• Readout of dummy frames (to prevent against large dark current integration) while the
camera waits for the next trigger event
The trigger delay is a few µs. The minimum pulse duration is 1 µs. The edge of trigger is pro-
grammable. The source of trigger is selectable between Camera Link CC1 signal and TTL_IO
trigger input. The period is defined by the programmable shutter time + readout time + wait.
Therefore the minimum period is reduced to 1 × readout time. As the integration time is not the
same for all lines (in the following timing diagram line n integration time is greater than line 1
integration time) this mode must be used with a pulsed light source or a shutter element. More-
over any residual light when shutter output signal is inhibited must be avoided. The exposure
time is defined by the shutter time and all the lines are exposed during the same time.
See register Aperture Shutter Time @ 246H Internal Register Mapping on
Table 4-3.
Label
Tsh
T1
Shutter Time Values at Triggered Mode without Full Reset
Description
Maximum shutter time (ms)
Step duration (µs)
2M60
655
10
2M30
1310
20
Figure 4-4.
Triggered Mode Without Full Reset Chronogram
Trigger In
Trigger N Event
Line 1
Integration
(Frame N)
Trigger Delay
Line1 Reset
Line 1 Readout
and Reset
Line n
Integration
(Frame N)
Line n Reset
Frame N
Readout
Line n Readout
and Reset
Shutter out
Programmable
Shutter Time
FVA
L
9
5440A–IMAGE–10/05