Isolated and Regulated 5 WATT Modular DC/DC Converters
FKC05 series
INPUT SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Input Voltage Ranges:
12 VDC Nominal
24 VDC Nominal
48 VDC Nominal
9-18 VDC
18-36 VDC
36-75 VDC
Oper. Temperature
Storage Temperature
Maximum Case Temp
MTBF
-25 to +71 DegC(FL)
-55 to +105 DegC *
100 DegC *
3.165 Million Hrs
MIL-HDBK-217F TA=25C (FL)
OUTPUT SPECIFICATIONS
Voltage and Current
See Selection Chart
PHYSICAL SPECIFICATIONS
Load Regulation (singles/duals) +/- 0.2% / +/- 1% (25%-FL)
Line Regulation
+/- 0.2% (singles/duals)
+/-0.02%/DegC
50mV Pk-Pk, typ
+/- 2%, typ
Case Material MKC03
Nickel-Coated Copper
with Non-Conductive Base
Fully Encapsulated
0.6 oz, (14g)
Temperature Coefficient
Ripple/Noise(Single/Dual)
Voltage Accuracy
Construction
Weight
Voltage Balance, Dual Outputs +/- 2%, typ
Short Circuit Protection
Continuous
GENERAL SPECIFICATIONS
Input-Out Isolation
Isolation Resistance
In/Out Capacitance
Efficiency
500VDC
10000 M Ohms
300 pF
FKC05-XXS(D)05
78%, typ
FKC05-XXS15,D12,D15 81%, typ
FKC05-XXS12
300Khz
82%, typ
Switching Frequency
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.
* These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
300 Myles Standish Blvd., Taunton, MA 02780
WWW.ASTRODYNE.COM
Ph: 1-800-823-8082
Fax: 508-823-8181