欢迎访问ic37.com |
会员登录 免费注册
发布采购

DU1P0-15D15 参数 Datasheet PDF下载

DU1P0-15D15图片预览
型号: DU1P0-15D15
PDF下载: 下载PDF文件 查看货源
内容描述: 孤立的和不管制1瓦模块化DC / DC转换器 [Isolated and Unregulated 1 WATT Modular DC/DC Converters]
分类和应用: 转换器
文件页数/大小: 3 页 / 376 K
品牌: ASTRODYNE [ ASTRODYNE CORPORATION ]
 浏览型号DU1P0-15D15的Datasheet PDF文件第1页浏览型号DU1P0-15D15的Datasheet PDF文件第3页  
Isolated and Unregulated 1 WATT Modular DC/DC Converters  
du1p0 series  
INpuT SpECIFICATIONS  
ENVIRONMENTAL SpECIFICATIONS  
Input Voltage Ranges:  
5 VDC Nominal  
12 VDC Nominal  
15 VDC Nominal  
24 VDC Nominal  
(Nom Vin, Full Load)  
See Selection Chart  
Capacitor  
4.5-5.5 VDC  
10.8-13.2 VDC  
13.5-16.5 VDC  
21.6-26.4 VDC  
Oper. Temperature  
Storage Temperature  
Relative Humidity  
MTBF (Note 2)  
Thermal Shock  
Vibration  
-25 to +85°C(See Derate Curve)  
-55 to +105°C *  
5% to 95% RH *  
1.471 MHrs  
Input Current  
Input Filter  
MIL-STD-810D  
10-55Hz, 10G, 30 Minutes  
along X, Y, and Z  
OuTpuT SpECIFICATIONS  
pHYSICAL SpECIFICATIONS  
Voltage and Current  
Load Regulation (Note 1)  
20% - FL  
See Selection Chart  
+/- 10% on 5V output  
+/- 8% on all others  
+/- 1.3%/1% of Vin  
+/-0.1%/°C max.  
100mV Pk-Pk, typ  
+/-5%, max  
Dimensions  
0.77 x 0.24 x 0.40”  
UL 94-V0 Non-Conductive  
Black Plastic  
Case Material  
Line Regulation (HL-LL)  
Temperature Coefficient  
Ripple/Noise(Single/Dual)  
Voltage Accuracy  
Construction  
Weight  
Fully Encapsulated (UL94-V0)  
2g (0.071oz)  
NOTES  
Short Circuit Protection  
Minimum Load (Note 1)  
Max. Load Capacitance  
1 Second max  
1) A Minimum 10% Load is required to maintain regulation  
2) BELLCORE TR-NWT-000332. Case 1: 50% Stress, Temperature at  
40°C. (Ground fixed and controlled environment)  
10% of FL  
Min Vin & Resitive Load  
See Selection Chart  
GENERAL SpECIFICATIONS  
Input-Out Isolation  
Efficiency (Nom I/P & FL)  
Switching Frequency  
Isolation Resistance  
Isolation Capacitance  
Safety  
1000VDC; (3000VDC suffix-N)  
See Selection Chart  
60Khz  
10000 M Ohms  
30pF, max.  
UL, TUV, CB, CE  
All specifications are typical at nominal input, full load, and 25DegC unless  
otherwise noted  
Astrodyne products are not authorized or warranteed for use  
as critical components in life support systems, equipment used  
in hazardous environments, nuclear controls systems, or other  
mission-critical applications.  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
300 Myles Stanꢀish Blvꢀ., Taꢁnton, MA 02780  
WWW.ASTROdYNE.COM  
ph: 1-800-823-8082  
Fax: 508-823-8181