欢迎访问ic37.com |
会员登录 免费注册
发布采购

ATC-24S 参数 Datasheet PDF下载

ATC-24S图片预览
型号: ATC-24S
PDF下载: 下载PDF文件 查看货源
内容描述: 10瓦的超小型模块式开关电源 [10 Watt Ultraminiature Modular Switching Power Supplies]
分类和应用: 开关
文件页数/大小: 3 页 / 246 K
品牌: ASTRODYNE [ ASTRODYNE CORPORATION ]
 浏览型号ATC-24S的Datasheet PDF文件第1页浏览型号ATC-24S的Datasheet PDF文件第3页  
10 Watt Ultraminiature Modular Switching Power Supplies  
ATC series  
ELECTRICAL SPECIFICATIONS  
Model No.  
( Dual Output )  
ATC-5D  
ATC-12D  
10W  
ATC-15D  
8W  
10W  
Max Output Wattage (W)  
Voltage  
90-264 VAC or 120-370 VDC  
47-440 Hz  
Frequency (Hz)  
Current (Full load)  
Inrush Current (<2ms)  
Leakage Current  
200 mA max. (115 VAC) / 130 mA max. (230 VAC)  
10 A max. (115 VAC) /20 A max. (230 VAC)  
0.75 mA max.  
Input  
External Fuse (recommend)  
Voltage (V.DC.)  
1.5 A slow blow type  
±5V  
±12V  
±380  
±15V  
±300  
Voltage Accuracy  
Current (mA) max  
Line Regulation (LL-HL) (typ.)  
Load Regulation (5-100%) (typ.)  
Minimum Load  
±2%  
±800  
±0.3%.  
±0.5%  
1%  
3%  
1%  
Output  
Maximum Capacitive Load  
Ripple  
470-23,000µF depending on model  
<0.2% Vout +40mV max (Vp-p)  
<0.5% Vout +50mV max (Vp-p)  
Noise  
Efficiency  
71%  
75%  
72%  
Hold-up Time  
15 ms min.  
Switching Frequency  
Over Power Protection  
Over Voltage Protection  
Short Circuit Protection  
Input-Output (V.AC)  
Input-FG (V.AC)  
100 kHz  
Hiccup technique, auto-recovery  
Protection  
Isolation  
Zener diode clamp  
Hiccup mode, indefinite (automatic recovery)  
3000V  
1500V  
Output-FG (V.AC)  
Operating Temperature  
Storage Temperature  
Temperature Coefficient  
Humidity  
500V  
-25°C…+70°C (with derating)  
-40°C…+85°C  
Environment  
±0.02%/°C  
95% RH  
MTBF  
>250,000 h @ 25°C (MIL-HDBK-217F)  
Dimension (L x W x H)  
Case Material  
2.52 x 1.77 x 0.85 Inches ( 64.0 x 45.0 x 21.5 mm ) Tolerance 0.5 mm  
Plastic resin with Fiberglass (flammability to UL 94V-0)  
Physical  
Weight  
100 g  
Cooling Method  
Free air convection  
UL/cUL, CE, TUV  
EN 55022 class B  
EN 50082-1  
Safety  
EMC  
Agency Approvals  
EMI (Conducted & Radiated Emission)  
EMS (Noise Immunity)  
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.  
300 Myles Standish Blvd., Taunton, MA 02780  
WWW.ASTRODYNE.COM  
Ph: 1-800-823-8082  
Fax: 508-823-8181