150W 2” x 4” Medical Grade Open Frame Switching Power Supplies ASM150 series  
INPUT SPECIFICATIONS  
GENERAL SPECIFICATIONS  
Input Voltage Range (AC / DC) 90-264 / 170-370  
I/P-O/P Isolation  
4000VAC for 1 Minute  
1500VAC for 1 Minute  
100VDC for 1 Minute  
500VAC for 1 Minute  
Input Current  
<2.5A @ 100VAC  
No Damage @ 230VAC Cold Start  
47-63Hz  
I/P-Ground Isolation  
O/P-O/P Isolation  
O/P-Ground Isolation  
Inrush Current  
Input Frequency  
Power Factor (90VAC)  
Harmonic Input Current  
Input Fuse  
0.98%  
Meets EN61000-3-2  
3A Internal Line & Neutral  
80VAC Auto Recover  
<275uA  
ENVIRONMENTAL SPECIFICATIONS  
Under Voltage Lockout  
Leakage Current (120V I/P)  
Oper. Temperature  
-20 to +50°C FL Derate Linearly to  
50% Load at 70°C *  
Cooling  
200LFM >100W O/P Power  
8-90% Non Cond (95% Non-Oper.)  
-40 to +80°C *  
Relative Humidity  
Storage Temperature  
Operating Altitude  
OUTPUT SPECIFICATIONS  
Setpoint Accuracy  
Overshoot during Power-on  
Voltage Adjust  
+/-1% Main Output V1  
Out of regulation 50mS, max.  
5% Main Output V1  
5000 ft Above Sea Level  
Derate to 40°C ambient @ 10,000 ft  
Convection Cooled: 150,000Hrs  
Air Flow (200 CFM): 300,000 Hrs  
EN55024  
MTBF  
Load Regulation  
+/-1% V1; +/-20% V2  
+/-0.1% 90-264VAC  
Line Regulation  
EMC / CE Mark Requirements  
Voltage Fluctuation  
ESD  
Cross Regulation  
+/-1% V1; +/-15% V2  
EN61000-3-3  
Transient Response  
(50% Load Change)  
Start Up (HL; FL)  
Rise / Hold Up Time  
Temperature Coefficient  
15KV Air, 8KV Contact  
10% Recover within 1mS  
500mS  
Radiated Field  
3V/m, 80-1000MHz 80% Modulation  
at distance of 3M  
20mS / 16mS  
+/-0.25mV/°C  
EFT  
±2kV on AC power port for 1 minute;  
±1kV on signal/ctrl lines  
Ripple/Noise: 20Mhz BW, resistive load, with 22uF (tantalum) and  
0.47uF (ceramic) parallel capacitors at POL  
1% of Output (42% 12V aux.)  
Surge  
±1kV line to line/±2kV line to earth  
on AC power port; ±0.5kV for outdoor  
cables  
Over-voltage Protection  
Over Current Protection  
130% max.  
Conducted RF  
3V; 0.15-80MHz 80% Modulation  
>95% dip, 0.5 period; 30% dip, 25  
periods; >95% reduction, 250 periods  
EN60601, IEC60601, UL/cUL60601  
130% max. Auto Recover*  
Voltage Variations  
Short Circuit and Over Temp Protection  
Auto Recovery *  
Safety Standards (PENDING)  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
Astrodyne products are not authorized or warranteed for use  
as critical components in life support systems, equipment used  
in hazardous environments, nuclear controls systems, or other  
mission-critical applications.  
All specifications are typical at nominal input, full load, and 25DegC unless  
otherwise noted  
ASTRODYNE USA: 1-800-823-8082  
ASTRODYNE PACIFIC: 886-2-26983458  
ASTRODYNE EUROPE: 353 51 561060  
WWW.ASTRODYNE.COM