1 5 0 W 2 ” x 4 ” M edical Grade Ope n Fram e S witc hing P ower S uppl i es
INPUT SPECIFICATIONS
Input Voltage Range (AC / DC)
Input Current
Inrush Current
Input Frequency
Power Factor (90VAC)
Harmonic Input Current
Input Fuse
Under Voltage Lockout
Leakage Current (120V I/P)
90-264 / 170-370
<2.5A @ 100VAC
No Damage @ 230VAC Cold Start
47-63Hz
0.98%
Meets EN61000-3-2
3A Internal Line & Neutral
80VAC Auto Recover
<275uA
ASM150
4000VAC for 1 Minute
1500VAC for 1 Minute
100VDC for 1 Minute
500VAC for 1 Minute
series
GENERAL SPECIFICATIONS
I/P-O/P Isolation
I/P-Ground Isolation
O/P-O/P Isolation
O/P-Ground Isolation
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature
Cooling
Relative Humidity
Storage Temperature
Operating Altitude
MTBF
EMC / CE Mark Requirements
Voltage Fluctuation
ESD
Radiated Field
EFT
Surge
-20 to +50°C FL Derate Linearly to
50% Load at 70°C
*
200LFM >100W O/P Power
8-90% Non Cond (95% Non-Oper.)
-40 to +80°C
*
5000 ft Above Sea Level
Derate to 40°C ambient @ 10,000 ft
Convection Cooled: 150,000Hrs
Air Flow (200 CFM): 300,000 Hrs
EN55024
EN61000-3-3
15KV Air, 8KV Contact
3V/m, 80-1000MHz 80% Modulation
at distance of 3M
±2kV on AC power port for 1 minute;
±1kV on signal/ctrl lines
±1kV line to line/±2kV line to earth
on AC power port; ±0.5kV for outdoor
cables
3V; 0.15-80MHz 80% Modulation
>95% dip, 0.5 period; 30% dip, 25
periods; >95% reduction, 250 periods
EN60601, IEC60601, UL/cUL60601
OUTPUT SPECIFICATIONS
Setpoint Accuracy
+/-1% Main Output V1
Overshoot during Power-on
Out of regulation 50mS, max.
Voltage Adjust
5% Main Output V1
Load Regulation
+/-1% V1; +/-20% V2
Line Regulation
+/-0.1% 90-264VAC
Cross Regulation
+/-1% V1; +/-15% V2
Transient Response
(50% Load Change)
10% Recover within 1mS
Start Up (HL; FL)
500mS
Rise / Hold Up Time
20mS / 16mS
Temperature Coefficient
+/-0.25mV/°C
Ripple/Noise: 20Mhz BW, resistive load, with 22uF (tantalum) and
0.47uF (ceramic) parallel capacitors at POL
1% of Output (42% 12V aux.)
Over-voltage Protection
130% max.
Over Current Protection
130% max. Auto Recover*
Short Circuit and Over Temp Protection
Auto Recovery
*
Conducted RF
Voltage Variations
Safety Standards (PENDING)
*
These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.