6 0 W, S i n gle O utp ut, Cla ss 2 LED Dr iver s
INPUT SPECIFICATIONS
Input Voltage ALD60
Max. Iin
Input Frequency
Max. Inrush Current
90-264 VAC (120/240 VAC Nominal)
1.5A @ 100 VAC Input
47-63Hz
30A @ 230VAC Input
25°C, cold start-up
ALD60
PHYSICAL SPECIFICATIONS
series
OUTPUT SPECIFICATIONS
Output Voltage/Current
See Model Chart
Output Voltage Adjust
+10/-25%
Max. Output Power
See Model Chart
Efficiency
83% typ. @ FL, 230 VAC Input
Hold Up Time
16mS @ FL, 100 VAC Input
Start Up Time
1 Second, typ.
Transient Response
4mS, FL to 1/2L, 100 VAC Input
Line Regulation
±1% max.
Load Regulation
±3% max.
Over Load Protection
Constant Current Limiting
*
Constant Current Mode Regulation
±3% max.
Constant Current Adjust
+5/-95%
Over Voltage Protection
130% max.
*
Short Circuit Protection
Hiccup Mode, Auto Recovery
*
Case / Design / Material / Color / Internal
NEMA 3 / Aluminum
White / Potted PCB
Mounting and Connection
Flange Mount, AC/DC Conduit
Entries, Knockouts for 1/2”
Conduit and Fittings
Size
9.68”L x 2.56”W x 2.05”H
Weight
1.94 lb (880g)
COMPLIANCE / SAFETY
EMI / RFI
Safety Standards
CISPR-22B, FCC-15B EMC
UL/CUL 1310, Class 2,
Outdoor Wet Locations
for UL 48 LED Lighting
CE EN60950
EN60529 - Weatherability of an
Enclosure - Rated to IP65
Weatherability Standard
ENVIRONMENTAL SPECIFICATIONS
MTBF
Cooling
Operating Temp.
Storage Temperature
55K Hrs, FL @ 25°C ambient,
Based on MIL-217F
Convection
-25°C to +60°C FL
-40°C to +85°C
*
These are stress ratings. Exposure of the devices to any of these conditions
may adversely affect long term reliability. Proper operation under conditions
other than the standard operating conditions is neither warranteed nor implied.
All specifications are typical at nominal input, full load, and 25DegC unless
otherwise noted
Astrodyne products are not authorized or warranteed for use
as critical components in life support systems, equipment used
in hazardous environments, nuclear controls systems, or other
mission-critical applications.