AHP6301 series  
INPUT SPECIFICATIONS  
PHYSICAL SPECIFICATIONS  
Input Voltage Range  
Frequency Range  
Input Current  
80-275 VAC (100-240 Nominal)  
47-63 Hz  
Size  
5.17” x 2.18” x 1.46”  
(131 x 55.4 x 37mm)  
Desktop Style  
Low Line (100VAC)  
High Line (240VAC)  
1.62A max.  
Construction  
Weight  
0.72A max.  
37A max.  
74A max.  
13.4oz (380g)  
Inrush Current, typ (Cold Start) Low Line (100VAC)  
High Line (240VAC)  
Flammability Rating  
UL94V-1  
Leakage Current (240 Vin)  
0.1mA  
ENVIRONMENTAL SPECIFICATIONS  
No Load Power Consumption  
0.5 Watts  
Oper. Temperature  
-10 to +40°C (FL) *  
50% Load @ 70°C  
OUTPUT SPECIFICATIONS  
(See Derate Curve Last Page)  
Free Air Convection  
Voltage and Current  
Output Power Range  
Load Regulation  
See Selection Charts  
Cooling  
0 to FL Rating  
Storage Temperature  
Operating Humidity  
EMC  
-40 to +85°C, 10~95% RH *  
0% to 95%, non-cond *  
Compliance to EN55011 (CISPR11),  
EN61000-3-2, -3 Class B  
100,000 Hrs  
±5%, max. 60%L, changing ±10%  
±1%, max. changing line ±10%  
110-150%, Auto-Recovery  
112-132%  
Line Regulation (FL)  
Over Load Protection*  
Over Voltage Protection*  
Short Circuit Protection  
Transient Response  
Temperature Coefficient  
Ripple/Noise (Note 1)  
Hold Up Time (Note 2)  
Start Up Time  
MTBF (MIL-HDBK-217F)  
Surge Voltage  
Auto Recovery  
2kV  
110Vin, FL  
4mS  
ESD - Air  
IEC61000-4-2, 8kV  
±0.04%/°C, typ  
100mV Pk-Pk max.  
100~240Vin, FL  
ESD - Contact  
IEC61000-4-2, 6kV  
Operating Altitude (Elevation)  
Vibration  
3000M  
12mS min.  
5G, 10 ~ 500Hz, 10min./1cycle,  
60min. each along X, Y, Z axes  
120cm, 1 ea. on six sides  
100~240Vin, FL 0.3S typ., 2S max.  
Drop Test  
GENERAL SPECIFICATIONS  
NOTES  
Input-Out Isolation  
Input-GND  
4000 VAC, Limit Current <10mA  
2800 VDC  
1. Ripple & noise is measured by using 20MHz bandwidth limited  
oscilloscope and terminated each output with a 0.47uF capacitor at  
rated load and nominal line.  
Isolation Resistance  
Efficiency  
50MΩ  
(FL, 230Vin) See Selection Chart  
ANSI/AAMI ES 60601-1:2005  
(UL/cUL 3rd Edition),  
EN 60601-1:2006  
Safety  
2. Hold up time is measured from the end of the last charging pulse to  
the time which the main output drops down to low limit of main output at  
rated load and nominal line.  
(TUV/T-mark 3rd Edition)  
AHP6301A, 6301C: Class I  
AHP6301B: Double Insulated  
Class II  
Protection Class  
* These are stress ratings. Exposure of the devices to any of these conditions  
may adversely affect long term reliability. Proper operation under conditions  
other than the standard operating conditions is neither warranteed nor implied.  
All specifications are typical at nominal input, full load, and 25°C unless other-  