Total Power:  
Input Voltage:  
200-350 Watts  
85-264 VAC  
120-300 VDC  
Single  
350 Watts  
# of Outputs:  
NTS350 Series  
Electrical Specs  
Input  
Input range  
Frequency  
Inrush current  
Efficiency  
85-264 VAC; 120-300 VDC  
47-440 Hz  
38 A max., cold start @ 25°C  
85% typical at full load  
EMI filter  
FCC Class B conducted and radiated  
CISPR 22 Class B conducted and radiated  
EN55022 Class B conducted and radiated  
VDE 0878 PT3 Class B conducted and  
radiated.  
Power factor  
0.99 typical  
Safety ground  
leakage current  
<0.5 mA @ 50/60 Hz, 264 VAC input  
Output  
Special Features  
Maximum power  
200W convection; 350 W with 30 CFM  
forced air  
5%  
• Active power factor correction  
• IEC EN6100-3-2 compliance  
• Remote sense  
• Power fail and remote inhibit  
• Single wire current sharing  
• Built-in EMI filter  
• Low output ripple  
• 5V standby  
• 12V fan output  
• Overvoltage protection  
• Overload protection  
• Thermal overload protection  
• DC power good  
• Built in OR-ing diode / FET  
• Optional fan cover (-CF suffix)  
Adjustment range  
Standby output  
Fan output  
5 V @ 2A regulated, 5%  
12 V @ 1A, -5 %, +7%, 0.5A for -CF version  
20 ms @ 350 W load, 115 VAC nominal  
line at factory voltage setting  
Short circuit protection on all outputs.  
Case overload protected @ 115-130%  
above peak rating  
Hold-up time  
Overload protection  
Overvoltage protection  
20% to 35% above nominal output  
Logic Control  
Power failure  
TTL logic signal goes high 100-500 msec  
after main output. It goes low at least 4  
msec before loss of regulation  
Requires an external contact closure to  
inhibit outputs  
TTL logic goes high after the output is in  
regulation. It goes low when there is loss  
of regulation.  
Remote on/off  
DC OK  
Environmental  
Remote sense  
Compensates for 0.5 V lead drop min.  
Will operate without remote sense  
connected. Reverse connection protected.  
Operating temperature: 0° to 50°C ambient  
derate each output at 2.5% per degree from 50° to  
70°C  
Electromagnetic susceptibility: Designed to meet  
EN61000-4, -2, -4, -5, -11 Level 3  
Humidity: Operating; non-condensing  
10% to 90%  
Safety  
Vibration: Three orthogonal axes, sweep at  
1 oct/min, 5 min. dwell at four major resonances  
2 G peak 8 Hz to 500 Hz, operational  
TUV  
UL  
CSA  
NEMKO  
AUSTEL  
CB  
60950  
60950  
60950  
60950  
60950  
Storage temperature: -40° to 85°C  
Temperature coefficient: .04% per °C  
MTBF demonstrated: >1M hours at full load and  
25°C ambient conditions  
Certificate and report  
Mark (LVD)  
CE  
Technical Support: (888) 41-ASTEC or (407) 241-2752  
Americas: (760) 930-4600 Europe (UK) 44 (1384) 842-211 Asia (HK) 852-2437-9662  
1