Rev. 1.30.06  
iMP Series  
2 of 8  
Output  
Adjustment range*  
Environmental  
Specifications  
10% minimum all outputs (manual)  
2
(full module adjustment range using I C)  
Margining  
Overall reg  
Ripple  
4-6% nominal analog (single output module only)  
0.4% or 20 mV max. (36W modules 4% max.)  
Operating  
-40° to 70°C ambient. Derate  
each output 2.5% per degree  
temperature  
from 50° to 70°C.  
( -20°C start up)  
RMS: 0.1% or 10 mV, whichever is greater  
Pk-Pk: 1.0% or 50 mV, whichever is greater  
Bandwidth limited to 20 MHz  
Storage  
-40°C to +85°C  
Dynamic response  
Recovery time  
<2% or 100 mV, with 25% load step  
temperature  
To within 1% in <300 μsec.  
Electromagnetic Designed to meet EN61000-  
2
susceptibility  
4; -2, -3, -4, -5, -6, -8, -11  
Level 3  
Overcurrent protection* Configurable through I C. Single output module and main out-  
put of the dual output module 105-120% of rated output cur-  
rent. Aux output of dual output module 105-140% of rated  
output current  
Humidity  
Operating; non-condensing  
10% to 95% RH  
Triple output module internally protected  
Vibration  
IEC68-2-6 to the levels of  
IEC721-3-2  
Short circuit protection  
Protected for continuous short circuit  
Recovery is automatic upon removal of short  
MTBF  
>550,000 hours at full load,  
demonstrated 220VAC and 25°C ambient  
conditions  
Overvoltage protection* Configurable through I2C  
Single output module  
Dual output module  
Triple output module  
2-5.5V 122-134% ; 6-60V 110-120%  
2-6V 122-134% ; 8-28V 110-120%  
No overvoltage protection provided  
Reverse voltage protection 100% of rated output current  
2
Safety  
Thermal protection*  
Configurable through I C  
All outputs disabled when internal temp exceeds safe operat-  
ing range. >5 ms warning (AC OK signal) before shutdown  
UL  
UL60950/UL2601  
CSA CSA22.2 No. 234 Level 5  
VDE EN60950/EN60601  
BABT Compliance to  
Remote sense  
Up to 0.5 V total drop (not available on triple output module)  
Singlewire parallel  
Configurable through firmware  
Current share to within 2% of total rated current  
EN 60950/EN60601 BS 7002  
Certificate and report  
Mark to LVD  
2
CB  
CE  
DC OK*  
+/-5% of nominal. Configurable through I C  
Minimum load  
Not required  
Housekeeping bias voltage 5 VDC @1.0Amp max. present whenever AC input is applied  
2
Module inhibit*  
Configured and controlled through I C  
250 kHz accepts external sync signal  
Switching frequency  
Output/Output isolation >1 Megohm, 500V  
2
VME signal*  
DC OK signal programmable through I C to function  
as POR signal  
*Can be controlled via I2C  
Output Module Line-up  
3
Module Code  
Module Type  
1
2
4
Dual  
None  
Triple  
Single  
Single  
Single  
Max output power  
210W  
35A  
2-60V  
25  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
360W  
60A  
2-60V  
25  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
750W  
150A  
144W  
10A  
2-6, 12-15, 28-30V  
36W  
2A  
8-28V 2-28V  
Max output current  
Output voltages available*  
Standard voltage increments  
Remote sense  
2-60V 5, 12-15, 28-30V  
25  
8-15V  
19  
18  
Yes  
No  
Yes  
No  
Yes  
No  
Yes  
No  
No  
No  
Yes  
No  
Yes  
No  
Yes  
No  
1
No  
No  
Yes  
No  
Yes  
No  
Yes  
No  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
Yes  
No  
3
Yes  
No  
Yes  
Yes  
Yes  
No  
Yes  
No  
No  
No  
Yes  
No  
Yes  
No  
Yes  
No  
Remote margin  
2
V-Program - I C Control  
Active Current Share  
2
Module Inhibit - I C Control  
Module Inhibit - Analog  
Over voltage / Over current protection  
Minimum load required  
Slots occupied in any iMP case  
1
2
1
*Programmable  
 复制成功!