欢迎访问ic37.com |
会员登录 免费注册
发布采购

AEQ60A24-198 参数 Datasheet PDF下载

AEQ60A24-198图片预览
型号: AEQ60A24-198
PDF下载: 下载PDF文件 查看货源
内容描述: 3-5.5Vdc输入, 1.2Vdc - 3.3VDC输出20W的DC -DC转换器 [3-5.5Vdc Input, 1.2Vdc - 3.3Vdc Output 20W DC-DC Converter]
分类和应用: 转换器
文件页数/大小: 15 页 / 182 K
品牌: ASTEC [ Astec America, Inc ]
 浏览型号AEQ60A24-198的Datasheet PDF文件第6页浏览型号AEQ60A24-198的Datasheet PDF文件第7页浏览型号AEQ60A24-198的Datasheet PDF文件第8页浏览型号AEQ60A24-198的Datasheet PDF文件第9页浏览型号AEQ60A24-198的Datasheet PDF文件第11页浏览型号AEQ60A24-198的Datasheet PDF文件第12页浏览型号AEQ60A24-198的Datasheet PDF文件第13页浏览型号AEQ60A24-198的Datasheet PDF文件第14页  
APA06 Non-Isolated Power SIPs  
3V-5.5V Input, 1.2V-3.3V Output, 9-20W Output  
Output Characteristics  
Input Characteristics  
Remote Sensing  
The APA06 power module has no internal  
fuse. An external fuse must always be  
employed! To meet international safety  
requirements, an input line fuse should be  
used. Input wires and copper coil must be  
capable of conducting a current of 1.5 times the  
value of the fuse. If one of the input lines is con-  
nected to chassis ground, then the fuse must  
be placed in the other input line.  
When the load can not be placed close to con-  
verter output pin, voltage drop will occur in dis-  
tribution. This voltage drop can be compensat-  
ed using sense lead. As shown in figure 3, con-  
necting sense pin close to the load, when the  
load changes, the module will automatically  
adjust the real output to maintain the constant  
voltage on the load.  
If not using the remote sense pin, leave it open.  
A fuse with ratings of 15A is recommended for  
2.5V and 3.3V output, and 10A for APA06 other  
products.  
Rline  
+V  
out  
Load  
Sense  
-V  
CNT Function  
The APA06 provides CNT function allowing the  
user to turn the output on and off using an  
external circuit such as figure 1 and figure 2.  
The control voltage-threshold is: 1.8V. For neg-  
ative control(negative logic N or positive logic P  
are optional), applying a voltage less than 1.8V  
to the CNT pin will enable the output, while  
applying a voltage greater than 2.4V will disable  
it. If not using CNT feature, leave the CNT  
pin open. The maximum voltage that can be  
applied to the control pin is 12 volts.  
out  
Fig.3 Sense Connection  
Output Trimming  
Output can be externally trimmed by using  
either method shown in figure 4.  
Users can increase or decrease the output volt-  
age set point of a module by connecting an  
external resistor between the TRIM pin and  
either the +Vout or GND pins. The trim resistor  
should be positioned close to the module. If not  
using the trim feature, leave the TRIM pin  
open.  
VI  
Vo  
CNT  
Trimming up or down by more than 16% of  
the nominal output may cause the converter  
to work improperly.  
GND  
Fig.1 Transistor CNT Control  
The trim formula for different output voltage are  
shown in figure 4 next page.  
VI  
Vo  
CNT  
GND  
Fig.2 Simple CNT Control  
-10-  
USA  
1-760-930-4600  
1-760-930-0698  
Europe  
44-(0)1384-842-211  
44-(0)1384-843-355  
Asia  
852-2437-9662  
852-2402-4426  
TEL:  
FAX:  
www.astec.com  
 复制成功!