Technical Reference Notes
AEO_ALO40/35/30/20/10x48 Series
(Single Output 8th Brick)
Electrical Specifications (continued)
OUTPUT SPECIFICATIONS
Parameter
Device
Symbol
Min
Typical
Max
Unit
Output Enable ON/OFF
Open collector TTL compatible
Positive Enable: Mod-ON
Mod-OFF
All
All
-
-
2.95
-0.50
-
-
20
1.20
V
V
Negative Enable: Mod-ON
Mod-OFF
All
All
-
-
-0.50
2.95
-
-
1.20
20
V
V
Note: 1. Derating curves for both openframe and baseplate modules are based on derated component junction
temperatures of 120oC or less where applicable.
2. Module is not internally fuesd; an external input line fuse is recommended for
use (e.g. Littlefuse® 465 Series / 250V min).
3. Refer to Figure 1 for the input ripple current test measurement setup.
4. Refer to Fig 2 for the output ripple and noise test measurement setup.
5. Output derating may apply at elevated ambient temperatures. Please refer to the appropriate derating curves.
6. Refer to the output trim equations provided (Equation 1 and 2).
SAFETY AGENCY / MATERIAL RATING / ISOLATION
Parameter
Safety Approval7
Device
All
UL/cUL 60950, 35d Edition – Recognized
EN 60950 through TUV
UL94V-0
Material Flammability Rating
Parameter
Input to Output Capacitance
All
Device
All
Symbol
Min
Typical
Max
Unit
pF
-
1000
-
Input to output Resistance
All
All
-
-
10
-
-
MOhms
-
Input to Output Insulation Type
Basic
Note: 7. The 3.3V, 5V and 12V modules have completed required safety approvals.
MODEL: AEO40x48 / ALO40x48 SERIES
JUNE 24, 2005 - REVISION B
SHEET 5 OF 30