Technical Reference Notes
AA60A-036L-050D033H Series
(5V / 3V3 Dual Output Half Brick)
Electrical Specifications
STANDARD TEST CONDITION on a single module unless otherwise specified.
TA:
25ºC (Ambient Air)
Return Pin for +VIN
Case Ground - OPEN
Dependent on model series1
48 VDC
- V :
PIN 1
PIN 2
PIN 3
PIN 4
PIN 5
PIN 6
PIN 7
PIN 8
PIN 9
PIN 10
IN
Case:
Enable:
+ V :
IN
+VOUT2
:
:
3.3V Load
-VOUT2
Trim2:
+VOUT1
- VOUT1
Trim1:
3.3V Load Return
3.3V Trim - Open
5V Load
5V Load Return
5V trim - Open
:
:
Note: 1. For Negative Enable series ("N" suffix), Enable pin should be connected to -Vin to allow module to turn-
on. For Positive Enable series (no "N" suffix), Enable pin should be connected to + Vin.
ABSOLUTE MAXIMUM RATINGS
Stresses in excess of the absolute maximum ratings can cause permanent damage to the converter. Functional
operation of the device is converter is not implied at these or any other conditions in excess of those given in the
operational section of the specs. Exposure to absolute maximum ratings for extended period can adversely affect
device reliability.
Parameter
Device
Symbol
Min
Typ
Max
Unit
Input Voltage:
Continuous
Transient(100ms) :
All
VIN
VI N, trans
0
0
-
-
60
100
Vdc
Vdc
Operating Ambient Temperature
Operating Baseplate Temp erature
TA
-40
-
-
702
ºC
ºC
TB
100
Storage Temperature
Operating Humidity
TSTG
-
-55
-
-
-
125
85
ºC
%
I/O Isolation
Input to Output
Input to Case
Output to Case
-
1500
707
1500
-
-
-
-
-
-
Vdc
Vdc
Vdc
Note: 2. Power Derating applies
MODEL: AA60A-036L-050D033H SERIES
OCTOBER 10, 2002 - REVISION A
SHEET 2 OF 12