Output Specification for
absolute encoders with Interbus interface
Excitation voltage
Excitation current
Interface
10 … 30 V
Interface HINT
Absolute Encoder
Interbus
250 mA
Interbus, ENCOM Profile K3 (progrmmable), K2
Binary 32 bit
Output code
Baud rate
500 kBaud
Data refresh
Resolution
Every 600 µs
12 (10 … 12) + 12 bit
Direction, preset, offset, resolution
Bus cover with T-manifold
EN 50081-2, 50082-2
Programmability
Connection
EMC
Differential signals (RS485)
ENCOM profile K3, K2, 32 bit,
binary process data
Data format
Interbus K2
DT format
Sµpi address
Byte no.
0
3
1
2
2
1
3
0
(according to the Phoenix company)
ID code K2
36 H (= 54 dec.)
37 H (= 55 dec.)
ID code K3
Signal names
Cable terminal no. (bus cover)
Signal wiring /
connection
UB +
GND
DI1
1
2
3
DI1
4
DO1
DO1
DO2
DO2
DI2
5
6
7
8
9
DI2
10
11
12
RBST
GND
ASM
CAT-WS-E-05
69
www.asm-sensor.com