 浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第6页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第7页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第8页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第9页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第11页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第12页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第13页浏览型号PCFP23-2500-L1-P1D-L02-M8的Datasheet PDF文件第14页  
POSICHRON®  
Description of Output Options  
Option - PMU for  
analog output  
U1, U2, U8 and I1  
Programming of the start and end value by the customer:  
The option PMU allows to program the start value and the end value of the output range  
by a programming signal SPAN/ZERO available at the connector. This Signal SPAN/ZERO  
must be connected with GND via a push button, then position magnet of the sensor must  
be moved to the start resp. end position. Pushing the button between 2 and 4 seconds sets  
the actual position as start position, pushing the button more than 5 seconds sets the actual  
position as end position. The values will be stored and are available after switching off the  
sensor.  
To reset the sensor to the factory values the button must be pushed for longer than two  
seconds when the sensor is switched on.  
Diagnostic on analog  
outputs  
Behaviour of the analog signal output in case of error  
In case of error (magnet missing or outside the measuring range) the analog output signal  
will assume a state according to the following options:  
Alarm_HIGH  
The output voltage resp. the output current is at HIGH level (overrange).  
Alarm_LOW  
The output voltage resp. the output current is at LOW level (underrange).  
Alarm_HOLD  
The output voltage resp. the output current will keep the last valid state.  
Alarm_HIGH  
Alarm_LOW  
Alarm_HOLD  
(standard)  
(.../U)  
(.../H)  
keeps last valid state  
(Order code U1/H)  
Uout ≥ 10,5 V  
Uout ≥ 10,5 V  
Uout ≥ 10 V  
U1  
U2  
U8  
I1  
Uout < 0,25 V  
(Order code U2/U)  
keeps last valid state  
(Order code U2/H)  
Uout < 0,25 V  
(Order code U8/U)  
keeps last valid state  
(Order code U8/H)  
1,5 ... 2 mA  
(Order code I1/U)  
keeps last valid state  
Iout ≥ 21 mA  
(Order code I1/H)  
Error signal for  
SSI output  
If the sensor cannot detect a magnet the position value will assume the maximum value  
(0xFFFFFFF).  
10/14  
DB-PCFP23-E-2013-11  