1
3.3 ms/sample
High-speed Performance and Reliability
■
Features
Sampling speed
Values in the ( ) show samples/second.
Frequency
50 Hz
60 Hz
FAST*
MEDIUM
SLOW
3.3
±1 ms (300)
130
±5 ms (8)
1,040
±50 ms (1)
3.3
±1 ms (300)
108
±5 ms (9)
1,080
±50 ms (1)
■
Samples at rates of up to 300 samples/sec.
(3.3 ms/sample)
■
Comparator function provides high-speed pass/fail evaluation
■
Equipped with external input and output for sequence control
■
Usefull Save/Load function helps work go faster
The
3237, 3238
and
3239
are equipped with a variety of
functions that help minimize tact time in production lines.
For details, see page 2.
Does not apply at resistances higher than 2MΩ, or LPΩ higher than 200kΩ (see page 5).
For the 3238 and 3239's frequency function gate time, see page 5.
* Approximately 55 ms required for self-calibration at 30-minute intervals.
■
True RMS value measurement
Both the
3237
and
3238
use true RMS measurement
for determination of distorted waveforms. In fact,
HIOKI
guarantees accuracy of the
3238
and
3239
for AC voltage of
10 Hz to 300 kHz, and AC current of 10 Hz to 30 kHz.
For specifications, see pages 5 and 6.
■
Low power resistance measurement function
prevents sample deterioration
The
3237, 3238
and
3239
use a low power Ω function to
minimize sample degradation when measuring resistance.
With this function, open terminal voltage never goes over 0.45
V DC, and measurement current never surpasses 100 µA DC.
For specifications, see pages 5 and 6.
■
Interface supports full remote operation
Measurement can be automated by using a controller to operate
the
3237
or
3238
through the GP-IB or RS-232C interface.
For details, see page 3.
■
Select from 3 types of units
The basic and economical
3237
37
38
32
32
32
39
The high-accuracy & multi-functional
3238
3239
✓
DC V basic accuracy: ±0.025% rdg.±2dgt.
✓
DC V basic accuracy: ±0.01% rdg.±2dgt.
✓
Includes frequency measurement for AC and DC A
DC voltage
AC voltage
[5 ranges, 199.999 mV to 1000.00 V]
[4 ranges, 1999.99 mV to 700.00 V]
2-terminal [7 ranges, 199.999
Ω
to 100.000 MΩ]
2-terminal [4 ranges, 1999.99
Ω
to 1999.99 MΩ]
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
For 4-terminal resistance measurement
Resistance
✓
DC V basic accuracy: ±0.01% rdg.±2dgt.
✓
All the functions of the 3238, plus 4-terminal
Ω
measurement
■
Reliable resistance measurement
using the 4-terminal measurement method
Using 4-terminal resistance
measurement, which is
unaffected by variables
such as measurement lead
wiring resistance, the
3239
displays outstanding
resistance measurement
capabilities.
Resistance LP
Continuity check
Diode check
[A buzzer sounds when resistance is less than 50.00
Ω]
[Anode-cathode voltage in the 1999.99 mV range]
Current measurement by
clamp sensor
AC/DC current
Frequency
4-terminal
4-terminal
[2 ranges, 199.999 mA and 1999.99 mA]
[5 ranges, 99.9999 Hz to 300.000 kHz]
Resistance
[5 ranges,199.999
Ω
to 1999.99 kΩ]
Resistance LP
[4 ranges,1999.99
Ω
to 1999.99 MΩ]
For clamp specifications, see page 4
For DIGITAL HiTESTER specifications, see pages 5 and 6