AWB31D9
5.2 Performance Table
Supply voltage = +5 V, TA = +25 C, ZO = 75
Parameter
Frequency
Gain
Typical
50
Unit
MHz
dB
500
20.3
-14.5
-16.0
41
1002
20.0
-24.0
-19.5
40
1200
19.9
-15.0
-17.0
36
20.7
-18.0
-20.0
38
S11
dB
S22
dB
Output IP31)
Output IP21),2)
Output P1dB
Noise Figure
CSO3)
dBm
dBm
dBm
dB
74
59
61
60
25
26
26
25
2.7
2.4
2.5
2.5
64
dBc
dBc
mA
V
CTB3)
65
Current
230
+5
Device Voltage
1) OIP3 and OIP2 are measured with two tones at an output power of +10 dBm/tone separated by 6 MHz.
2) OIP2 is measured at F1+F2 Frequency.
3) CSO & CTB measured at Pout = 97 dBV flat for NTSC 79 channels + QAM 256 75 channels, -6 dB offset.
5.3 Plot of S-parameter & Stability Factor
40
30
10
9
8
7
6
5
4
3
2
1
0
S21
S11
20
10
0
-10
-20
-30
-40
-50
-60
S12
K
S22
0
200
400
600
800 1000 1200
Frequency (MHz)
9/21
ASB Inc.
sales@asb.co.kr
June 2017