SMT06C Series
5 V i n a n d 1 2 V i n s i n g l e o u t p u t
DC-DC CONVERTERS C Class Non-isolated
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
NEW Product
OUTPUT
POWER
(MAX.)
OUTPUT
CURRENT
(MIN.)
OUTPUT
CURRENT
(MAX.)
REGULATION
INPUT
OUTPUT
VOLTAGE
EFFICIENCY
(TYP.)
MODEL
NUMBER (11,12)
VOLTAGE
LINE
LOAD
20 W
30 W
4.5-5.5 Vdc
0.9-3.3 Vdc
0.9-5.0 Vdc
0 A
0 A
6 A
6 A
89%
91%
0.2%
0.2%
0.5%
0.5%
SMT06C-05SADJJ
SMT06C-12SADJJ
10.2-13.8 Vdc
Part Number System with Options
S M T 0 6 C - 1 2 S A D J J
Product Family
Packaging Options (11)
SMT = Surface Mount
J = Pb-free (RoHS 6/6 compliant)
Rated Output Current
Number of Outputs
SADJ = Single Adjustable Output
06 = 6 A
Performance
C = Cost Optimized
Input Voltage
05 = 4.5 Vdc to 5.5 Vdc
12 = 10.2 Vdc to 13.8 Vdc
Output Voltage Adjustment of the SMT06C Series
The ultra-wide output voltage trim range offers major advantages to users who
select the SMT06C series. It is no longer necessary to purchase a variety of
modules in order to cover different output voltages. The output voltage can be
trimmed in a range of 0.9 Vdc to 5.0 Vdc. When the SMT06C series converter
leaves the factory the output has been adjusted to the default voltage of 0.9 V.
Notes
Ripple and Noise Specification
Output
1
di/dt = 10 A/µs, Vin = Nom, Tc = 25 °C, load change = 0.50 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
Model
Pk - Pk
RMS
2
3
Measured with external filter. See Application Note 169 for details.
Power up is the time from application of dc input to Power Good high.
Remote ON/OFF asserted high to Power Good high.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured as per recommended set-up. Cin = 270 µF (20 mΩ ESR
max.). Cout = 680 µF (10 mΩ ESR max.).
Voltage
5 V input models 0.9 Vdc to 2.5 Vdc
3.3 Vdc
30 mV
40 mV
15 mV
15 mV
4
5
6
12 V input models 0.9 Vdc to 2.5 Vdc
3.3 Vdc to 5 Vdc
40 mV
50 mV
20 mV
20 mV
Uses external resistor from trim to ground. Minimum value 485 Ω for 5 V
model, 280 Ω for 12 V model. See Application Note 169 for details.
Signal line assumed <3 m.
7
8
9
External input fusing recommended.
See Application Note 169 for operation above 50 ºC.
10 See Application Note 169 for more details.
11 TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool
at http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
International Safety Standard Approvals
UL/cUL CAN/CSA 22.2 No. 60950
UL 60950 File No. E139421
TÜV Product Service (EN60950:2000)
Certificate No. B 04 08 19870 228
CB report and certificate to US/6415C/UL
File Name: smt06c.pdf Rev (03): 15 Dec 2005