IMP
ENVIRONMENTAL SPECIFICATIONS
Operating temperature
Storage temperature
Electromagnetic susceptibility
Humidity
-40 °C to 70 °C ambient. Derate each output 2.5% per degree from 50 °C to 70 °C. (-20 °C start up)
-40 °C to +85 °C
Designed to meet EN61000-4; -2, -3, -4, -5, -6, -8, -11 Level 3
Operating; non-condensing 10% to 95% RH
Vibration
IEC68-2-6 to the levels of IEC721-3-2
MTBF demonstrated
> 550,000 hours at full load, 220 Vac and 25 °C ambient conditions
OUTPUT MODULE LINE-UP
—
Triple
36 W
2 A
Module Code
Module Type
1
2
3
5
4
Dual
Single
210 W
35 A
Single
360 W
60 A
Single
750 W
150 A
Single
1500 W
300 A
Max output power
144 W
10 A
Max output current
Output voltages available
Standard voltage increments
2 to 60 V 2 to 60 V 2 to 60 V 2 to 60 V
2 to 28 V
16
2 to 28 V
18
25
25
25
18
V1
V2
Yes
No
V1,V2,V3
No
Remote sense
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Remote margin
No
V-Program - I2C Control
Active Current Share
Module Inhibit - I2C Control
Module Inhibit - Analog
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
Yes
No
Yes
No
Overvoltage/Overcurrent
protection
Yes
Yes
Minimum load required
No
1
No
2
No
3
No
4
No
No
No
1
Slots occupied in any iMP
case
1
4
advancedenergy.com