EXQ125 Series
DC/DC CONVERTERS
•
Ultra-high efficiency topology, 91% at 3.3V,
88% typical at 1.8V
•
Industry standard footprint
•
Wide baseplate temperature, -40°C to +100°C
•
90% to 110% output trim
•
No minimum load
•
Overvoltage protection
•
Remote on/off
Single output
36-100W High Efficiency DC/DC Converters
1
The EXQ125 is a new ultra-high efficiency, open frame, isolated converter series in
an industry standard quarter-brick footprint that provides up to 100 watts of output
power. The EXQ125 delivers very high output current at low voltages, and excellent
useable power density for today’s high end applications. The seven models in the
series feature an input voltage range of 33 to 75VDC and are available in output
voltages of 12V, 5V, 3.3V, 2.5V, 1.8V, 1.5V and 1.2V. The output voltage on each
model is adjustable from 90% to 110% of the nominal value. The EXQ125 series
also has a remote on/off capability. Overcurrent and overvoltage protection features
are included as standard. With full international safety approval including EN60950
(TÜV Rheinland) and UL/cUL1950, the EXQ125 reduces compliance costs and time
to market.
TÜV
2 YEAR WARRANTY
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
Set point accuracy
Line regulation
Load regulation
Minimum load
Overshoot
Undershoot
Ripple and noise
Transient response
(See Note 1)
INPUT SPECIFICATIONS
Input voltage range
Input current
Input current (max.)
(See Note 3)
Input reflected ripple
(See Note 5)
48Vin nominal
No load
Remote OFF
33 to 75VDC
85mA
20mA
3.5A max. @ Io max.
and Vin = 33 to 75V
300mA (pk-pk) typ.
(See Note 7)
Open collector ref to -input
Open circuit or >4.0VDC
<1.2VDC
32.5V (typ)
30.5V (typ)
6ms (typ)
2ms (typ)
At turn-on and turn-off
1.2V, 1.5V, 1.8V, 2.5V
and 3.3V models
5Hz to 20MHz
Low line to high line
Full load to min. load
90% to 110%
±1.5% max.
±0.1% max.
0.2% max.
0A
None
None
60mV pk-pk
20mV rms
2% typ. deviation
100µs recovery to
within 1% of setpoint
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (DC power)
Conducted (signal)
Input transients
EN55022 (See Note 2)
EN55022 (See Note 2)
EN55022
Level A
Level B
Level B
EN61000-4-2 8kV (NP), 15kV (NP)
EN61000-4-2 6kV (NP), 8kV (NP)
EN61000-4-3 10V/m (NP)
EN61000-4-6 10V (NP)
EN61000-4-6 10V (NP)
ETS 300 132-2, ETR 283
GENERAL SPECIFICATIONS
Efficiency
Operational
Switching frequency
Approvals and
standards (See Note 4)
Material flammability
Weight
MTBF
MIL-HDBK-217F
@ 25°C, 100% load
ground benign
Input/output
Input/baseplate
Fixed
See table
1500VDC
1500VDC
400kHz typ.
EN60950 (TÜV Rheinland)
UL/cUL1950
UL94V-0
45g (1.6oz)
>300,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
Operating baseplate
temperature
Non-operating
-40°C to +100°C
-40°C to +125°C
Active high remote ON/OFF
Logic compatibility
ON
OFF
Undervoltage lockout
Start-up time
(See Note 6)
Power up
Power down
Power up
Remote ON/OFF
File Name: EXQ125S.PDF Rev: 18 June 2002