欢迎访问ic37.com |
会员登录 免费注册
发布采购

EXB250-48S1V8 参数 Datasheet PDF下载

EXB250-48S1V8图片预览
型号: EXB250-48S1V8
PDF下载: 下载PDF文件 查看货源
内容描述: 单路输出 [Single output]
分类和应用:
文件页数/大小: 2 页 / 62 K
品牌: ARTESYN [ ARTESYN TECHNOLOGIES ]
 浏览型号EXB250-48S1V8的Datasheet PDF文件第1页  
DC/DC CONVERTERS
|
72-165W DC/DC
72 to 165 Watt
High efficiency DC/DC converters
OUTPUT
POWER
(MAX.)
72W
90W
108W
150W
165W
165W
165W
Notes
1
2
di/dt = 0.1A/µs, Vin = 48VDC, Tc = 25°C, load change = 0.5 lo max. to
0.75 lo max. and 0.75 lo max. to 0.5 lo max.
The EXB250 meets level A and level B conducted emissions only with
external components connected before the input pins to the converter.
See Application Note 119.
Recommended input fusing is a 10A HRC 200V rated fuse.
This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
Measured with no external Pi filter. Significant reduction possible with
external filter. See Application Note 119.
Start-up into resistive load.
Active low remote On/Off is available. Standard product is active high.
When ordering active low parts, designate with the Suffix '-R', e.g
EXB250-48S3V3-R.
When ordering 0.145" pin lengths designate with the Suffix'-N', if the
product is already a '-R' suffix product then the suffix will be '-RN'
When ordering 0.110" pin lengths designate with the Suffix'-K', if the
product is already a '-R' suffix product then the suffix will be '-RK
INPUT
VOLTAGE
33-75VDC
33-75VDC
33-75VDC
33-75VDC
33-75VDC
33-75VDC
33-75VDC
OVP
1.44VDC
1.8VDC
2.2VDC
3.0VDC
4.0VDC
6.0VDC
14.4VDC
OUTPUT
VOLTAGE
1.2V
1.5V
1.8V
2.5V
3.3V
5.0V
12.0V
OUTPUT
CURRENT
(MIN.)
0A
0A
0A
0A
0A
0A
0A
OUTPUT
CURRENT
(MAX.)
60A
60A
60A
60A
50A
33A
13.75A
EFFICIENCY
(TYP.)
84.0%
85.5%
87.0%
88.0%
90.0%
91.7%
92.0%
REGULATION
LINE
±0.2%
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
±0.1%
LOAD
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
±0.2%
MODEL
NUMBER
(7,8,9)
EXB250-48S1V2
EXB250-48S1V5
EXB250-48S1V8
EXB250-48S2V5
EXB250-48S3V3
EXB250-48S05
EXB250-48S12
PROTECTION
Short circuit protection
Overvoltage protection
TELECOM SPECIFICATION
Central office interface A
ETS300-132-2, input voltage
and current requirements
Continuous
Non-latching clamp
3
4
5
6
7
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
8
9
PIN CONNECTIONS
PIN NUMBER
1
2
3
4
5
6
7
8
9
FUNCTION
+Vin
Remote On/Off
No Function
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
0.200 [5.08]
0.190 [4.83]
2.000
[50.80]
4
Ø0.040
(7 PLS)
5
Ø0.080
(2 PLS)
1.700 [43.18]
1.300 [33.02]
1.000 [25.40]
0.700 [17.78]
0.300 [7.62]
0.000 [0.00]
0.500 [12.70]
6
BOTTOM
7
VIEW
8
2
3
1
9
*0.21 [5.33]
M3x0.5 Threaded
Through (4 PLS)
2.280 [57.91]
*Standard available pin length.
0.145 (3.68) and 0.110 (2.79)
options also available. (See
Notes 8 and 9 for ordering details).
TOP
VIEW
2.400
[60.96]
ALL DIMENSIONS IN INCHES [mm]
1.900 [48.26]
Ø0.128 [Ø3.25]
(4 PLS)
Ø0.094 [Ø2.39]
(2 PLS)
1
2
3
4
9
8
7
6
5
0.000 [0.00]
0.300 [7.62]
0.700 [17.78]
1.300 [33.02]
1.700 [43.18]
Ø0.054 [Ø1.37]
(7 PLS)
1.000 [25.40]
Recommended Hole Pattern
DS_EXB250S_20020621.PDF
Data Sheet © Artesyn Technologies® 2002
The information and specifications contained in this data sheet are believed to be correct at time of publication. However, Artesyn Technologies accepts no responsibility for consequences arising
from printing errors or inaccuracies. Specifications are subject to change without notice. No rights under any patent accompany the sale of any such product(s) or information contained herein.
Please consult our website for the following items:
http://www.artesyn.com
Full Data Sheet
Application Note
PAGE 2