EXA40 Series  
S i n g l e o u t p u t  
DC/DC CONVERTERS 40W High Efficiency DC/DC Converters  
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm  
INPUT SPECIFICATIONS  
MINIMUM  
TYPICAL  
MAXIMUM  
Remote ON/OFF  
Active low, control to -Vin,  
open collector input  
Open circuit voltage  
ON  
OFF  
4.5V  
5.5V  
1.0V  
2.5V  
Remote ON/OFF source current  
-70µA  
-100µA  
INPUT  
VOLTAGE  
OUTPUT  
VOLTAGE  
NOMINAL  
OUTPUT VOLTAGE  
OUTPUT  
CURRENT (MAX.)  
TYPICAL  
EFFICIENCY  
MODEL  
NUMBER  
(2)  
(1)  
18-36VDC  
18-36VDC  
18-36VDC  
18-36VDC  
36-75VDC  
36-75VDC  
36-75VDC  
36-75VDC  
1.5 to 2.0V  
2.5 to 3.0V  
3.0 to 3.6V  
4.5 to 5.5V  
1.5 to 2.0V  
2.5 to 3.0V  
3.0 to 3.6V  
4.5 to 5.5V  
1.8V  
2.75A  
3.3V  
5.0V  
1.8V  
2.75V  
3.3V  
5.0V  
8.0A  
8.0A  
8.0A  
8.0A  
8.0A  
8.0A  
8.0A  
8.0A  
84%  
EXA40-24S1V8  
EXA40-24S2V75  
EXA40-24S3V3  
EXA40-24S05  
87%  
88%  
90%  
84%  
EXA40-48S1V8  
EXA40-48S2V75  
EXA40-48S3V3  
EXA40-48S05  
86%  
88%  
91%  
Notes  
EMC CHARACTERISTICS (Continue d)  
1
True latching OVP is available as an option. Please add the suffix ‘-Vto the  
model number, e.g. EXA40-24S1V8-V. Additional alphanumeric suffixes  
maybe added to indicate minor modifications not affecting the safety  
approvals.  
Guaranteed minimum output voltage range.  
Latching OVP response time is 1ms (typical). OVP latch is reset by toggling  
remote ON/OFF or by recycling the input voltage.  
Figures are percentage of minimum input voltage.  
Rshort 20m.  
ETS 300 386-1 table 5  
Conducted emissions  
(See Design Note 101)  
EN55022, internal filter  
Level A  
and 4.7µF film cap  
EN55022, external filter,  
EN55022 (See Design Note)  
EN61000-4-2, level 3  
EN61000-4-2, level 4  
EN61000-4-5, level 3,4  
EN61000-4-4, level 3,4  
EN61000-4-3, level 3  
EN61000-4-6, level 3  
Level B  
Level B  
2
3
Radiated emissions  
ESD air  
ESD contact  
Surge (500V)  
Fast transients  
Radiated immunity  
Conducted immunity  
4
5
6
TVS spec : 6V8 @ 10mA, 10V5 @ 57A  
4V1 @ 1mA, 7V3 @ 50A  
Maximum continuous output power.  
7
40 Watts for S05 models  
26.4 Watts for S3V3 models  
GENERAL SPECIFICATIONS  
22 Watts for S2V75 models  
14.4 Watts for S1V8 models.  
User must provide recommended fuses in order to comply with safety  
approvals.  
Maximum temperature on components Q100, Q102 and Q103 not to  
exceed 120°C. See Application Note for details.  
Efficiency  
See table  
1500VDC  
Basic insulation  
Input/output  
8
9
Input fuse 24V  
Input fuse 48V  
(See Note 8)  
3.5A slow blow  
2.0A slow blow  
Switching frequency  
Fixed  
300kHz  
Approvals and  
standards  
(See Notes 1, 7, 8, 9)  
EN60950  
EXA40-24S05  
All other Models  
DERATING CURVE  
Output Power (% )  
Bi-national UL1950  
(See Notes 1, 7, 8, 9)  
CSA C22.2 No. 234/950  
100%  
75%  
50%  
25%  
0%  
Weight  
25g (0.88 oz)  
MTBF, See Design Note MIL-HDBK-217  
250,000 hours  
ENVIRONMENTAL SPECIFICATIONS  
Thermal performance  
Operating ambient  
temperature  
Non-operating  
-40°C to +70°C,  
See curves  
-55°C to +105°C  
27.5%  
Over temperature  
shutdown  
Loss of Function  
Self-Recovery (LFS)  
75°C to +85°C  
-40°C -30°C-20°C -10°C  
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C 100°C  
AMBIENT TEMPERATURE (°C)  
ETS 300 019-2-3  
Air temperature  
Classes T3.1 to T3.5  
Figure 1: Natural Convection (0.1m/s) Typical derating, See Application Note.  
Low: IEC 68-2-1  
High: IEC 68-2-2  
Change: IEC 68-2-1  
-40°C  
+70°C  
-40°C to +70°C  
Relative humidity  
IEC 68-2-56  
IEC 68-2-30  
10% to 100% RH  
Condensation  
CAUTION: Hazardous internal voltages and high temperatures.  
Ensure that unit is not user accessible.  
Vibration, Class 3M5  
IEC68-2-6  
2 to 9 Hz, 3mm disp.  
9 to 200Hz 1g  
MIL-STD-202F  
IEC-68-2-29  
MIL-STD-202F  
Method 204 cond. A  
Shock, Class 3M5  
Method 213B cond. A  
Please consult our website for the following items: Application Note Shortform Data Sheet  
www.a rte s yn.com  
File Name: LF_EXA40.PDF Rev: 15 Jan 2002